2018-08-07 07:18:59 | 1ST REVIEW: |
| 2017 FLORIDA BUILDING CODE 6TH EDITION |
| 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH |
| EDITION |
| 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION |
| 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH |
| EDITION |
| 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH |
| EDITION |
| |
| PLUMBING COMMENTS: |
| |
| 1. THE ACCESSIBILITY CODE REQUIRES A MINIMUM OF 1 SINK |
| IN EACH TYPE OF ACCESSIBLE ROOM COMPLY WITH FBC ACC |
| 606. PER FBC ACC 212.3 |
| |
| 2. SHT. P0.1 THE SANITARY ISOMETRIC IS MISSING THE |
| FOLLOWING PLUMBING FIXTURES, ALL THE SINKS IN THE SONO |
| ROOMS, THE LAVATORY AND URINAL IN THE MENS BATHROOM |
| PLEASE CLARIFY, PER WPB AMEND TO FBC 107.2.1 |
| |
| 3. SHT. P0.1 BOTH THE SANITARY AND WATER ISOMETRIC |
| DRAWING ARE TO COMPACT AND CONGESTED TO DETERMINE CODE |
| COMPLIANCE PLEASE EXPAND THE SANITARY AND WATER |
| ISOMETRIC DRAWINGS, PER WPB AMEND TO FBC 107.2.1 |
| |
| 4. SHT. P0.1 THE SANITARY ISOMETRIC THE SINK IN EXAM |
| ROOM #4 AND LAB SHALL CONNECT TO THE BUILDING DRAIN |
| SEPARATELY THE THE BATHROOM GROUP. PER FBC PL 912.1 |
| |
| 5. ALL LAVATORY'S USED BY THE PUBLIC SHALL HAVE ONLY |
| TEMPERED WATER AND SHALL BE DELIVERED THROUGH AN |
| APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT |
| CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5 |
| |
| 6. SHT. P0.1 THE WATER ISOMETRIC IS MISSING THE |
| FOLLOWING PLUMBING FIXTURES, THE MEN AND WOMENS |
| BATHROOMS M PLEASE CLARIFY, PER WPB AMEND TO FBC |
| 107.2.1 |
| |
| |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| THE PREVIOUSLY REVIEWED SHEETS. |
| |