Date |
Text |
2018-08-28 16:22:55 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, |
| FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: |
| |
| PLEASE CONSIDER THE FOLLOWING AS PROVISO: |
| |
| THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED |
| AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE |
| PROVISO COMMENTS WILL RESULT IN A FAILED FIRE |
| INSPECTION. |
| |
| |
| 1) SHEET A 0.10 - THE LIFE SAFETY PLAN INDICATES REAR |
| EXIT SIGNS LEADING THRU THE STORAGE AREA. |
| |
| PER NFPA 101, CHAPTER 7,MEANS OF EGRESS |
| |
| 7.5.1.6 EXIT ACCESS FROM ROOMS OR SPACES SHALL BE |
| PERMITTED TO BE THROUGH ADJOINING OR INTERVENING ROOMS |
| OR AREAS, PROVIDED THAT SUCH ROOMS OR AREAS ARE |
| ACCESSORY TO THE AREA SERVED. FOYERS, LOBBIES, AND |
| RECEPTION ROOMS CONSTRUCTED AS REQUIRED FOR CORRIDORS |
| SHALL NOT BE CONSTRUED AS INTERVENING ROOMS. EXIT |
| ACCESS SHALL BE ARRANGED SO THAT IT IS NOT NECESSARY TO |
| PASS THROUGH ANY AREA IDENTIFIED UNDER PROTECTION FROM |
| HAZARDS IN CHAPTERS 11 THROUGH 43. |
| |
| A STORAGE ROOM IS IDENTIFIED AS ONE OF THESE AREAS. |
| |
| HOWEVER, ONLY ONE EXIT IS REQUIRED FROM THE MAIN |
| MERCANTILE AREA AND ONE FROM THE STORAGE ROOM. |
| |
| 36.2.4 NUMBER OF MEANS OF EGRESS. |
| 36.2.4.1 MEANS OF EGRESS SHALL COMPLY WITH ALL OF THE |
| FOLLOWING, |
| EXCEPT AS OTHERWISE PERMITTED BY 36.2.4.2 THROUGH |
| 36.2.4.5: |
| (1) THE NUMBER OF MEANS OF EGRESS SHALL BE IN |
| ACCORDANCE WITH |
| SECTION 7.4. |
| (2) NOT LESS THAN TWO SEPARATE EXITS SHALL BE PROVIDED |
| ON EVERY |
| STORY. |
| (3) NOT LESS THAN TWO SEPARATE EXITS SHALL BE |
| ACCESSIBLE FROM |
| EVERY PART OF EVERY STORY. |
| |
| 36.2.4.3 A SINGLE MEANS OF EGRESS SHALL BE PERMITTED IN |
| A CLASS C |
| MERCANTILE OCCUPANCY, PROVIDED THAT THE TRAVEL DISTANCE |
| TO THE EXIT |
| OR TO A MALL PEDESTRIAN WAY (SEE 36.4.4.2) DOES NOT |
| EXCEED 75 FT |
| (23 M). |
| |
| MOVE ONE EXIT SIGN IN THE HALL LEADING TO THE FRONT |
| EXIT AND REMOVE THE ONE OVER THE STORAGE ROOM DOOR. |
| |
| |
| 2) ANY WORK OF THE FIRE SPRINKLER AND/OR FIRE ALARM |
| SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS. |
| |
| |
| PETER LEDUC |
| FIRE MARSHAL |
| 561-804-4709 |
| [email protected] |
| |