2018-06-08 07:05:46 | THE PLAN HAS BEEN PASSED PROVISIONALLY: FAILURE TO |
| CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| ASSESSMENT OF RE-INSPECT FEE(S) |
| |
| 1. PROVIDE PANEL SCHEDULE AND LOAD CALCULATION BY FINAL |
| INSPECTION. PERMIT REFERENCED BY CONTRACTOR #18040526 |
| IS A STAND ALONE SERVICE CHANGE PERMIT WITH NO PANEL |
| SCHEDULE OR LOAD CALCULATION. |
| |
| 2. EGRESS LIGHTING REQUIRED AT ALL ENTRANCES/EXIT DOORS |
| TO THE DWELLING EXECPT THE (VEHICLE DOOR) FOR THE |
| GARAGE. FOR DWELLING UNITS, ATTACHED GARAGES, AND |
| DETACHED GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL |
| SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON |
| THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE |
| LEVEL ACCESS. PROVIDE CORRECTION. NEC 210.70(A)(2)(B), |
| FBC RE E3903.3 |
| |
| 3. VALUE HAS BEEN ADJUSTED TO 4500$ THE INCREASED VALUE |
| OF 1000$ ADDED TO THE INITIAL 2000$ TO MAKE 3000$ TOTAL |
| IS INSUFFICIENT. |
| |
| |
| FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE 2017 6TH ED. |
| FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| 6TH EDITION |
| FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE |