Plan Review Notes
Plan Review Notes For Permit 18050188
Permit Number 18050188
Review Stop B
Sequence Number 1
Notes
Date Text
2018-05-12 07:37:51BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE SITE PLAN. SHOW TOTAL NUMBER OF PARKING
 SPACES. SHOW LOCATION OF ACCESSIBLE SPACES AND
 ACCESSIBLE ROUTE TO ACCESSIBLE ENTRANCE.
 2. TOTAL NUMBER OF ACCESSIBLE SPACES BASED ON TOTAL
 NUMBER OF SPACES PROVIDED PER FBC ACCESSIBILITY TABLE
 208.2
  
 TABLE 208.2
  
 PARKING SPACES
 TOTAL NUMBER OF PARKING SPACES PROVIDED IN PARKING
 FACILITY MINIMUM NUMBER OF REQUIRED ACCESSIBLE PARKING
 SPACES
 1 TO 25 1
 26 TO 50 2
 51 TO 75 3
 76 TO 100 4
 101 TO 150 5
 151 TO 200 6
 201 TO 300 7
 301 TO 400 8
 401 TO 500 9
 501 TO 1000 2 PERCENT OF TOTAL
 1001 AND OVER 20, PLUS 1 FOR EACH 100, OR FRACTION
 THEREOF, OVER 1000
  
 ADVISORY 208.2 MINIMUM NUMBER. THE TERM ?PARKING
 FACILITY? IS USED SECTION 208.2 INSTEAD OF THE TERM
 ?PARKING LOT? SO THAT IT IS CLEAR THAT BOTH PARKING
 LOTS AND PARKING STRUCTURES ARE REQUIRED TO COMPLY WITH
 THIS SECTION. THE NUMBER OF PARKING SPACES REQUIRED TO
 BE ACCESSIBLE IS TO BE CALCULATED SEPARATELY FOR EACH
 PARKING FACILITY; THE REQUIRED NUMBER IS NOT TO BE
 BASED ON THE TOTAL NUMBER OF PARKING SPACES PROVIDED IN
 ALL OF THE PARKING FACILITIES PROVIDED ON THE SITE
  