2018-05-03 18:04:27****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. INSTALLATION SCHEDULE EDGE DISTANCE STATES "NA".
 THIS INFORMATION IS REQUIRED. NOTE THAT PAGE 13 HAS A
 TABLE OF FACTORS FOR REDUCED EDGE DISTANCE. PROPOSED
 SPACING MAY NOT COMPLY DEPENDING ON EDGE DISTANCE.
  
 FOR TAPCONS, EDGE DISTANCE LESS THAN 3" REQUIRES A .35
 FACTOR APPLIED TO THE SPACING WHICH IS NOT POSSIBLE FOR
 THE OPTIONS SELECTED. FBC R 301.
  