Plan Review Notes For Permit 18041046 |
Permit Number |
18041046 |
|
Review Stop |
R |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2018-06-29 09:14:05 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1) ROOFING PERMIT REQUIRED. REMOVE REFERENCES TO METAL | | ROOFING FROM THIS MASTER SET, NO OPTION USES METAL | | ROOFING. INDICATE THE CEMENT ROOF TILE AND ATTACHMENT | | METHOD THAT WILL BE USED BY MARKING THE APPROPRIATE | | INFORMATION ON THE PLANS. FBC 107.2.1 IF AN ADHESIVE | | WILL BE USED, SUBMIT THE PRODUCT APPROVAL FOR IT. FBC | | 107.3.4 IF A MORTAR OR ADHESIVE SET IS USED SUBMIT THE | | PRODUCT APPROVAL FOR THE UNDERLAYMENT TO SHOW THAT IT | | WILL MEET WINDLOADS. SEE INSTALLATION NOTE 6.2 ON PAGE | | 5 OF THE TILE PRODUCT APPROVAL. | | | | |
|