Plan Review Notes
Plan Review Notes For Permit 18040836
Permit Number 18040836
Review Stop B
Sequence Number 1
Notes
Date Text
2018-06-12 17:38:24BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017).
  
 1-IMPACT FEES
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
 2- PROVIDE SITE PLAN THAT INCLUDES COMPLETE INFORMATION
 FOR DRAINAGE AS REQUIRED BY SEC. 107.2.5 CITY
 AMENDMENTS.
  
 SEC. 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS
 SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE
 ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE
 AND LOCATION OF NEW CONSTRUCTION AND EXISTING
 STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE
 ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED
 GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS
 APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN
 FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE
 WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE
 SURVEY. IN THE CASE OF DEMOLITION, THE SITE PLAN SHALL
 SHOW CONSTRUCTION TO BE DEMOLISHED AND THE LOCATION AND
 SIZE OF EXISTING STRUCTURES AND CONSTRUCTION THAT ARE
 TO REMAIN ON THE SITE OR PLOT. THE BUILDING OFFICIAL IS
 AUTHORIZED TO WAIVE OR MODIFY THE REQUIREMENT FOR A
 SITE PLAN WHEN THE
 APPLICATION FOR PERMIT IS FOR ALTERATION OR REPAIR OR
 WHEN OTHERWISE WARRANTED.
  
 3- SHEET G100:
 A) CODE REVIEW INFORMATION REFERENCES FLORIDA
 ACCESSIBILITY CODE 2014 AND FLORIDA PLUMBING CODE 2014.
 THE CURRENT CODE IS THE 2017 CODE. REVISE AS REQUIRED.
 CHAPTER 553 F.S.
  
 B) OCCUPANCY CLASSIFICATION IS NOT CLEAR. CODE REVIEW
 INFORMATION SPECIFIES BUSINESS AND LIGHT STORAGE S-2
 OCCUPANCIES, WHILE INFORMATION ON SHEET S301 SPECIFIES
 OCCUPANCY CLASSIFICATION F-1. REVISE AS REQUIRED TO
 MATCH. SEC. 302.1 FBC.
  
 C) CONSTRUCTION TYPE IS NOT CLEAR. CODE REVIEW
 SPECIFIES CONSTRUCTION TYPE III-B, WHILE INFORMATION ON
 SHEET S301 SPECIFIES CONSTRUCTION TYPE II. REVISE AS
 REQUIRED. SEC. 601.1 FBC.
  
 D) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR 2
 HOUR FIRE RATED EXTERIOR WALLS ASSEMBLY AS REQUIRED TO
 COMPLY WITH SEC. 602.3 FBC FOR TYPE III-B CONSTRICTION.
 COORDINATE WITH ITEM #3D ABOVE.
  
 E) OCCUPANCY LOAD SPECIFIED ON CODE REVIEW IS NOT CLEAR
 AND IT DOESN'T MATCH INFORMATION SHOWN ON FLOOR PLANS
 ON SHEET A-300. IN ADDITION, NEED TO SPECIFY THE
 OCCUPANT LOAD OF THE MEZZANINE. SEC. 1004.1 FBC AND
 TABLE 1004.1.2 FBC.
  
 F)EGRESS INFORMATION IN CODE REVIEW IS INCOMPLETE AND
 NEED TO BE UPDATED. PROVIDE THE MAXIMUM TRAVEL DISTANCE
 (INCLUDING MEZZANINE) AND UPDATE CITED TABLES. SEE 2017
 FBC FOR CORRECT TABLES AND SECTIONS.
 PROVIDE MAXIMUM TRAVEL DISTANCE ON PLANS, INCLUDING
 FROM MEZZANINE. NOTE: SEE SEC. 1017.3 FBC FOR
 MEASUREMENT OF TRAVEL DISTANCE.
  
 4- SHEET S-300:
 A) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR ALL
 THE TIE BEAMS OF TWO STORY REINFORCED CONCRETE BLOCK
 WALL. SEC. 1604.1 FBC.
  
 B) IT LOOKS LIKE THE ANCHORS SPECIFIED TO SUPPORT
 (2)2X6 STRUCTURAL WOOD LEDGER FOR THE MEZZANINE FLOOR
 TRUSSES MIGHT NOT BE ADEQUATE TO SUPPORT ALL THE LIVE
 AND DEAD LOADS. THIS MEZZANINE IS USED FOR STORAGE. SEE
 TABLE 1607.1 FBC FOR REQUIRED LIVE LOADS. PROVIDE
 ENGINEERING ANALYSIS SHOWING COMPLIANCE WITH ALL THE
 DEAD AND LIVE LOADS. COORDINATE WITH COMMENTS ON SHEET
 S3001.
  
 C) ACCORDING TO PLANS SUBMITTED, IT LOOKS LIKE THE WEST
 TWO STORY HIGH WALL MAY NOT HAVE ENOUGH VERTICAL
 REINFORCEMENT. PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS (INCLUDING LOCATION) FOR VERTICAL
 REINFORCEMENT SHOWING HOW THE WALL WILL RESIST ALL THE
 LATERAL LOADS. SEC. 107.2.1.2 CITY AMENDMENTS.
  
 D) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 ROOF TRUSSES AND FLOOR TRUSSES STRUCTURAL CONNECTORS.
 SEC. 1601.1 FBC. (NOTE: CLARIFY WHY ALL THE BUILDING
 SECTIONS SHOW BAR JOISTS INSTEAD OF WOOD TRUSSES).
  
 E) CLEARLY SPECIFY FOOTING SIZES. SEC. 1801.2 FBC.
 NOTE: COORDINATE WITH ACCESSIBLE ENTRY TO AVOID
 CONFLICTS. ALSO, TAKE INTO CONSIDERATION THE 12"
 REQUIREMENT BELOW GRADE.
  
 5- SHEET S-301:
 A) DESIGN NOTES REFERENCE THE 2014 FBC. THE CURRENT
 CODE IS 2017, 6TH EDITION. REVISE AS REQUIRED. CHAPTER
 553 F.S.
  
 B) REVISE THE LIVE AND DEAD DESIGN LOADS. NOTE: SEE
 TABLE 1607.1 FBC FOR THE MINIMUM UNIFORMLY DISTRIBUTED
 LIVE LOADS AND MINIMUM CONCENTRATED LIVE LOADS AND
 REVISE ALL LIVE LOADS ACCORDINGLY.
  
 C)ACCORDING TO SEC. 1609.4 FBC THIS BUILDING IS LOCATED
 IN EXPOSURE "C" NOT EXPOSURE "B". REVISE AS REQUIRED
 AND REVISE ALL COMPONENTS AND CLADDING DESIGN PRESSURES
 ACCORDINGLY. NOTE: CONVERT THE ULTIMATE WIND LOADS VULT
 TO NOMINAL WIND LOADS VASD FOR COMPONENTS AND CLADDING.
  
 D) PROVIDE COMPLETE WIND DESIGN CRITERIA AS REQUIRED BY
 SEC. 1603.1.4 FBC. INCLUDE THE RISK CATEGORY (TABLE
 1604.5) AND APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 E) COORDINATE CONSTRUCTION TYPE AND OCCUPANCY
 CLASSIFICATION WITH SHEET G100.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 6- SHEET A-100:
 A) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 THE ACCESSIBLE ROUTE SEC. 206 AND 502 FBC
 ACCESSIBILITY. PROVIDE DIMENSIONS, REVISE ACCESS AISLE.
 ETC.
  
 B) CLEARLY IDENTIFY THE PROPERTY LINES AND PROVIDE
 DIMENSIONS. SEC. 107.2.1 CITY AMENDMENTS.
  
 C) PROVIDE COMPLETE STRUCTURAL DETAILS AND
 SPECIFICATIONS FOR ALL THE PROPOSED POST AND PANEL
 CONCRETE WALL AND CORRUGATED ALUMINUM GATES SHOWN ON
 THE SITE PLAN. COORDINATE WITH INFORMATION SHOWN ON
 EXTERIOR ELEVATIONS AND SECTIONS. SEC. 106.1 FBC.
  
 7- SHEET A-300:
 A)PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 THE ACCESSIBLE ROUTE SEC. 206.2.1 AND 402.2 FBC
 ACCESSIBILITY.
  
 B)PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 CONSTRUCTION OF THE STAIRS SHOWING COMPLIANCE WITH LIVE
 LOADS TABLE 1607.1 FBC. PROVIDE COMPLETE DIMENSIONS,
 INCLUDING THE WIDTH IN ALL AREAS. SPECIFY TREADS AND
 RISER DIMENSIONS TO SHOW COMPLIANCE WITH SEC. 1011.5.2
 FBC.
  
 C) PROVIDE HANDRAILS ON EACH SIDE OF THE STAIRWAY AS
 REQUIRED BY SEC. 1011.11 FBC.
  
 D)PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS
 FOR THE CONSTRUCTION OF THE ALUMINUM CANOPY ON THE EAST
 WALL. SEC. 1601.1 FBC.
 NOTE: CLEARLY SPECIFY HEADROOM.
  
 E) PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS
 FOR THE ROOF HATCH OPENING. SEC. 1601.1 FBC. NOTE:
 PROVIDE ROOF HATCH OPENING DIMENSIONS SHOWING
 COMPLIANCE WITH SEC. 1011.12.2 FBC.
  
 8- PROVIDE SECTION/DETAIL SHOWING COMPLIANCE WITH THE
 HEADROOM BY THE DOOR TO THE OFFICE AREA FROM THE
 WAREHOUSE AREA. SEC. 1208.2 FB.
  
 9- ENERGY CALCULATIONS SUBMITTED:
 A) ARCHITECT OF RECORD NEED TO SIGN AND PROVIDE
 PROFESSIONAL LICENSE NUMBER AS REQUIRED BY SEC.
 C103.1.1.1.2 FBC-ENERGY CONSERVATION. NOTE: ENVELOPE
 INFORMATION SHOWN ON THE ENERGY CALCULATIONS IS NOT
 PROVIDED ON THE PLANS SUBMITTED. FOR EXAMPLE CHECK THE
 BELOW GRADE WALL, INSULATION, SLAB EDGE INFORMATION,
 ETC. REVIEW ENERGY CALCULATIONS AND SIGN AS REQUIRED.
  
 B) ENERGY CALCULATIONS NEED TO BE CERTIFIED (SIGNED) BY
 THE BUILDING OWNER OR ANY AUTHORIZED PERSONS AS
 REQUIRED BY SEC. C103.1.1.2 FBC-ENERGY CONSERVATION.
  
 10- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
 A) SWING ENTRY DOORS AS SHOWN ON PLANS.
  
 B) OVERHEAD DOORS AS SHOWN ON PLANS.
  
 C) ROOF HATCH AS SHOWN ON PLANS.
  
 D) PRECAST LINTELS AS SHOWN ON PLANS.
  
 E) PETERSEN ALUMINUM SIDING AS SHOWN ON PLANS.
  
 F) STOREFRONT WINDOWS AS SHOWN PLANS. NOTE: IDENTIFY
 GLAZING/ MULLIONS. FOR ALL PRODUCTS WITH GLAZING,
 PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF
 GLAZING, MULLION INFORMATION IF REQUIRED, ATTACHMENTS
 AND ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2017
 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL
 BE INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURERS
 INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE
 PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED
 BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS.
  
 G) ANY STRUCTURAL CONNECTORS SPECIFIED ON PLANS AND
 SECTIONS.
  
 H) FLAT ROOF. AND CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. 1609.1 FBC. NOTE: IF THE
 SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES FOR
 ALL ROOF ZONES, THEN SIGNED AND SEALED RAS 117
 CALCULATIONS ARE REQUIRED.
  
 11- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4 CITY AMENDMENTS.
  
 12- PROVIDE COMPLETE TRUSS PACKAGE (2 SIGNED AND SEALED
 COPIES) REVIEWED AND APPROVED BY THE DESIGNER OF
 RECORD. SEC. 107.3.4 CITY AMENDMENTS.
  
 13- PERMIT FOR PROTECTION OF PEDESTRIANS BARRIER AND
 COVERED WALKWAY WILL BE REQUIRED BY TABLE 3306.1 FBC
 BEFORE CONSTRUCTION.
  
 14- PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY
 REVIEWED DRAWINGS. DO NOT STAPLE OLD DRAWINGS TO PLANS.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  