Plan Review Notes
Plan Review Notes For Permit 18040509
Permit Number 18040509
Review Stop P
Sequence Number 2
Notes
Date Text
2018-06-06 16:13:132ND REVIEW: FBC 2017 6TH EDITION
  
 PLUMBING COMMENTS:
  
 1. SHT. P-1 THE SHOWER IN THE MASTER BATHROOM SHALL
 CONNECT DOWN STREAM OF THE LAVATORY'S THERE CAN BE ONLY
 ONE FIXTURE UPSTREAM OF THE VENT. PER FBC RES P3108.2.1
  
 2. SHT P-1 THERE SHALL BE A VENT BETWEEN THE TUB AND
 THE SHOWER FOR THE GUEST BATHROOMS. PER FBC RES
 P3108.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  