Plan Review Notes
Plan Review Notes For Permit 18031329
Permit Number 18031329
Review Stop B
Sequence Number 1
Notes
Date Text
2018-03-30 10:23:232017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 18031329
 ADD: 3932 LAKE TAHOE CIR.
 CONT: BEST CHOICE ROOFING
 TEL: 561-305-2097
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. MARCH 30/ 2018
 ACTION: DENIED
  
 1) PERMIT APPLICATION STATES 3/12 PITCH, 2 STORY REROOF
 USING POLYGLASS TU PLUS, DIRECT DECK, IGP FOAM, & BORAL
 VILLA 900 TILE.
  
 1A) THE ROOFING APPROVAL FL7849-R11 IS A PENDING ROOF
 PRODUCT APPROVAL WITH 28 SUB-SYSTEMS. THE FINAL
 APPROVED FL 7849-R11 ONLY HAS 20 APPROVED SUB-SYSTEMS
 AND THE VILLA 900 IS NOT ONE OF THEM. THE UES
 EVALUATION REPORT IS NOT PART OF THIS FLORIDA APPROVAL.
 RE-SUBMIT AN APPROVED FLORIDA OR MIAMI-DADE PRODUCT
 APPROVAL.
  
 1B) THE FLORIDA APPROVAL FL6332-R8 ICP ADHESIVES
 POLYSET AH-160 WAS SUBMITTED. THE CONTRACTOR HAS NOT
 IDENTIFIED IN TABLE 1 THE TYPE TILE MATERIAL, CLAY OR
 CONCRETE, PROFILE, ADHESIVE PADDY PLACEMENT, SINGLE OR
 DOUBLE, SIZE OF PADDY AND ALLOWABLE OVERTURNING MOMENT.
  
 1C) TABLE 2 HIP AND RIDGE TILE IN ICP ADHESIVES POLYSET
 AH-160 ALSO NOT FILLED OUT. CODE COMPLIANCE CANNOT BE
 DETERMINED.
  
 1D) PAGES 5-9 OF THE POLYSET AH-160 NOT IDENTIFIED AS
 TO WHICH APPLICATION APPLIES. CODE COMPLIANCE CANNOT BE
 DETERMINED.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved