Date |
Text |
2018-03-30 16:25:55 | 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 18031224 |
| ADD: 8993 OKEECHOBEE BLVD. SUITE: 112 |
| CONT: TBD/ TO BE DETERMINED |
| TEL: 404-904-4941 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: FRI. MARCH 30/ 2018 |
| ACTION: DENIED |
| |
| 1) THE TITLESHEET T.1 INDICATES THIS BUILDING IS TYPE |
| II-B CONSTRUCTION. SHEET A1 NOTES WALL TYPE P3 |
| CONSTRUCTION 8FEET TALL AND OF WOOD CONSTRUCTION, 2X4 |
| STUDS @16 INCHES O.C. PLEASE REVIEW THE REQUIRED |
| CONSTRUCTION FOR TYPE II-B CONSTRUCTION. SEE : |
| |
| 2017 FBC-B 603.1.3.(1) FIRE-RETARDANT-TREATED WOOD |
| SHALL BE PERMITTED IN: |
| 1.1. NONBEARING PARTITIONS WHERE THE REQUIRED |
| FIRE-RESISTANCE RATING IS 2 HOURS OR LESS. |
| EXCEPTIONS: |
| 11. PARTITIONS DIVIDING PORTIONS OF STORES, OFFICES OR |
| SIMILAR PLACES OCCUPIED BY ONE TENANT ONLY AND THAT DO |
| NOT ESTABLISH A CORRIDOR SERVING AN OCCUPANT LOAD OF 30 |
| OR MORE SHALL BE PERMITTED TO BE CONSTRUCTED OF |
| FIRE-RETARDANT-TREATED WOOD, 1-HOUR |
| FIRE-RESISTANCE-RATED CONSTRUCTION OR OF WOOD PANELS OR |
| SIMILAR LIGHT CONSTRUCTION UP TO 6 FEET (1829 MM) IN |
| HEIGHT. |
| |
| 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS ST. |
| WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |