2018-04-09 10:24:33 | BUILDING PLAN REVIEW |
| 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER, PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| 1ST REVIEW |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. SIGN IS LOCATED IN A FLOOD HAZARD AREA. |
| 2. DESIGN TO BE SIGNED AND SEALED BY A FLORIDA LICENSED |
| PROFESSIONAL ENGINEER. |
| 3. DESIGN TO ADDRESS THE FOLLOWING: |
| CITY OF WEST PALM BEACH MUNICIPAL CODE, ARTICLE VII, |
| SECTIONS 18-284 AND 18-296. |
| FBC CHPT. 16 SECTIONS 1612.1 AND 1612.4 |
| |
| SEC. 18-284. - SITE PLANS AND CONSTRUCTION DOCUMENTS. |
| (A) |
| INFORMATION FOR DEVELOPMENT IN FLOOD HAZARD AREAS . THE |
| SITE PLAN OR CONSTRUCTION DOCUMENTS FOR ANY DEVELOPMENT |
| SUBJECT TO THE REQUIREMENTS OF THIS ARTICLE SHALL BE |
| DRAWN TO SCALE AND SHALL INCLUDE, AS APPLICABLE TO THE |
| PROPOSED DEVELOPMENT: |
| (1) |
| DELINEATION OF FLOOD HAZARD AREAS, FLOODWAY BOUNDARIES |
| AND FLOOD ZONE(S), BASE FLOOD ELEVATION(S), AND GROUND |
| ELEVATIONS IF NECESSARY FOR REVIEW OF THE PROPOSED |
| DEVELOPMENT. |
| (2) |
| WHERE BASE FLOOD ELEVATIONS OR FLOODWAY DATA ARE NOT |
| INCLUDED ON THE FIRM OR IN THE FLOOD INSURANCE STUDY, |
| THEY SHALL BE ESTABLISHED IN ACCORDANCE WITH SUBSECTION |
| 18-284(B)(2) OR (3) OF THIS ARTICLE. |
| (3) |
| WHERE THE PARCEL ON WHICH THE PROPOSED DEVELOPMENT WILL |
| TAKE PLACE WILL HAVE MORE THAN 50 LOTS OR IS LARGER |
| THAN FIVE ACRES AND THE BASE FLOOD ELEVATIONS ARE NOT |
| INCLUDED ON THE FIRM OR IN THE FLOOD INSURANCE STUDY, |
| SUCH ELEVATIONS SHALL BE ESTABLISHED IN ACCORDANCE WITH |
| SUBSECTION 18-284(B)(1) OF THIS ARTICLE. |
| (4) |
| LOCATION OF THE PROPOSED ACTIVITY AND PROPOSED |
| STRUCTURES, AND LOCATIONS OF EXISTING BUILDINGS AND |
| STRUCTURES. |
| (5) |
| LOCATION, EXTENT, AMOUNT, AND PROPOSED FINAL GRADES OF |
| ANY FILLING, GRADING, OR EXCAVATION. |
| (6) |
| WHERE THE PLACEMENT OF FILL IS PROPOSED, THE AMOUNT, |
| TYPE, AND SOURCE OF FILL MATERIAL; COMPACTION |
| SPECIFICATIONS; A DESCRIPTION OF THE INTENDED PURPOSE |
| OF THE FILL AREAS; AND EVIDENCE THAT THE PROPOSED FILL |
| AREAS ARE THE MINIMUM NECESSARY TO ACHIEVE THE INTENDED |
| PURPOSE. |
| (7) |
| EXISTING AND PROPOSED ALIGNMENT OF ANY PROPOSED |
| ALTERATION OF A WATERCOURSE. |
| THE FLOODPLAIN ADMINISTRATOR IS AUTHORIZED TO WAIVE THE |
| SUBMISSION OF SITE PLANS, CONSTRUCTION DOCUMENTS, AND |
| OTHER DATA THAT ARE REQUIRED BY THIS ARTICLE BUT THAT |
| ARE NOT REQUIRED TO BE PREPARED BY A REGISTERED DESIGN |
| PROFESSIONAL IF IT IS FOUND THAT THE NATURE OF THE |
| PROPOSED DEVELOPMENT IS SUCH THAT THE REVIEW OF SUCH |
| SUBMISSIONS IS NOT NECESSARY TO ASCERTAIN COMPLIANCE |
| WITH THIS ARTICLE. |
| (B) |
| INFORMATION IN FLOOD HAZARD AREAS WITHOUT BASE FLOOD |
| ELEVATIONS (APPROXIMATE ZONE A) . WHERE FLOOD HAZARD |
| AREAS ARE DELINEATED ON THE FIRM AND BASE FLOOD |
| ELEVATION DATA HAVE NOT BEEN PROVIDED, THE FLOODPLAIN |
| ADMINISTRATOR SHALL: |
| (1) |
| REQUIRE THE APPLICANT TO INCLUDE BASE FLOOD ELEVATION |
| DATA PREPARED IN ACCORDANCE WITH CURRENTLY ACCEPTED |
| ENGINEERING PRACTICES. |
| (2) |
| OBTAIN, REVIEW, AND PROVIDE TO APPLICANTS BASE FLOOD |
| ELEVATION AND FLOODWAY DATA AVAILABLE FROM A FEDERAL OR |
| STATE AGENCY OR OTHER SOURCE OR REQUIRE THE APPLICANT |
| TO OBTAIN AND USE BASE FLOOD ELEVATION AND FLOODWAY |
| DATA AVAILABLE FROM A FEDERAL OR STATE AGENCY OR OTHER |
| SOURCE. |
| (3) |
| WHERE BASE FLOOD ELEVATION AND FLOODWAY DATA ARE NOT |
| AVAILABLE FROM ANOTHER SOURCE, WHERE THE AVAILABLE DATA |
| ARE DEEMED BY THE FLOODPLAIN ADMINISTRATOR TO NOT |
| REASONABLY REFLECT FLOODING CONDITIONS, OR WHERE THE |
| AVAILABLE DATA ARE KNOWN TO BE SCIENTIFICALLY OR |
| TECHNICALLY INCORRECT OR OTHERWISE INADEQUATE: |
| A. |
| REQUIRE THE APPLICANT TO INCLUDE BASE FLOOD ELEVATION |
| DATA PREPARED IN ACCORDANCE WITH CURRENTLY ACCEPTED |
| ENGINEERING PRACTICES; OR |
| B. |
| SPECIFY THAT THE BASE FLOOD ELEVATION IS TWO FEET ABOVE |
| THE HIGHEST ADJACENT GRADE AT THE LOCATION OF THE |
| DEVELOPMENT, PROVIDED THERE IS NO EVIDENCE INDICATING |
| FLOOD DEPTHS HAVE BEEN OR MAY BE GREATER THAN TWO FEET. |
| (4) |
| WHERE THE BASE FLOOD ELEVATION DATA ARE TO BE USED TO |
| SUPPORT A LETTER OF MAP CHANGE FROM FEMA, ADVISE THE |
| APPLICANT THAT THE ANALYSES SHALL BE PREPARED BY A |
| FLORIDA LICENSED ENGINEER IN A FORMAT REQUIRED BY FEMA, |
| AND THAT IT SHALL BE THE RESPONSIBILITY OF THE |
| APPLICANT TO SATISFY THE SUBMITTAL REQUIREMENTS AND PAY |
| THE PROCESSING FEES. |
| (C) |
| ADDITIONAL ANALYSES AND CERTIFICATIONS . AS APPLICABLE |
| TO THE LOCATION AND NATURE OF THE PROPOSED DEVELOPMENT |
| ACTIVITY, AND IN ADDITION TO THE REQUIREMENTS OF THIS |
| SECTION, THE APPLICANT SHALL HAVE THE FOLLOWING |
| ANALYSES SIGNED AND SEALED BY A FLORIDA LICENSED |
| ENGINEER FOR SUBMISSION WITH THE SITE PLAN AND |
| CONSTRUCTION DOCUMENTS: |
| (1) |
| FOR DEVELOPMENT ACTIVITIES PROPOSED TO BE LOCATED IN A |
| REGULATORY FLOODWAY, A FLOODWAY ENCROACHMENT ANALYSIS |
| THAT DEMONSTRATES THAT THE ENCROACHMENT OF THE PROPOSED |
| DEVELOPMENT WILL NOT CAUSE ANY INCREASE IN BASE FLOOD |
| ELEVATIONS; WHERE THE APPLICANT PROPOSES TO UNDERTAKE |
| DEVELOPMENT ACTIVITIES THAT DO INCREASE BASE FLOOD |
| ELEVATIONS, THE APPLICANT SHALL SUBMIT SUCH ANALYSIS TO |
| FEMA AS SPECIFIED IN SUBSECTION 18-284(D) OF THIS |
| ARTICLE AND SHALL SUBMIT THE CONDITIONAL LETTER OF MAP |
| REVISION, IF ISSUED BY FEMA, WITH THE SITE PLAN AND |
| CONSTRUCTION DOCUMENTS. |
| (2) |
| FOR DEVELOPMENT ACTIVITIES PROPOSED TO BE LOCATED IN A |
| RIVERINE FLOOD HAZARD AREA FOR WHICH BASE FLOOD |
| ELEVATIONS ARE INCLUDED IN THE FLOOD INSURANCE STUDY OR |
| ON THE FIRM AND FLOODWAYS HAVE NOT BEEN DESIGNATED, |
| HYDROLOGIC AND HYDRAULIC ANALYSES THAT DEMONSTRATE THAT |
| THE CUMULATIVE EFFECT OF THE PROPOSED DEVELOPMENT, WHEN |
| COMBINED WITH ALL OTHER EXISTING AND ANTICIPATED FLOOD |
| HAZARD AREA ENCROACHMENTS, WILL NOT INCREASE THE BASE |
| FLOOD ELEVATION MORE THAN ONE FOOT AT ANY POINT WITHIN |
| THE CITY. THIS REQUIREMENT DOES NOT APPLY IN ISOLATED |
| FLOOD HAZARD AREAS NOT CONNECTED TO A RIVERINE FLOOD |
| HAZARD AREA OR IN FLOOD HAZARD AREAS IDENTIFIED AS ZONE |
| AO OR ZONE AH. |
| (3) |
| FOR ALTERATION OF A WATERCOURSE, AN ENGINEERING |
| ANALYSIS PREPARED IN ACCORDANCE WITH STANDARD |
| ENGINEERING PRACTICES WHICH DEMONSTRATES THAT THE |
| FLOOD-CARRYING CAPACITY OF THE ALTERED OR RELOCATED |
| PORTION OF THE WATERCOURSE WILL NOT BE DECREASED, AND |
| CERTIFICATION THAT THE ALTERED WATERCOURSE SHALL BE |
| MAINTAINED IN A MANNER WHICH PRESERVES THE CHANNEL'S |
| FLOOD-CARRYING CAPACITY; THE APPLICANT SHALL SUBMIT THE |
| ANALYSIS TO FEMA AS SPECIFIED IN SUBSECTION 18-284(D) |
| OF THIS ARTICLE. |
| (D) |
| SUBMISSION OF ADDITIONAL DATA . WHEN ADDITIONAL |
| HYDROLOGIC, HYDRAULIC OR OTHER ENGINEERING DATA, |
| STUDIES, AND ADDITIONAL ANALYSES ARE SUBMITTED TO |
| SUPPORT AN APPLICATION, THE APPLICANT HAS THE RIGHT TO |
| SEEK A LETTER OF MAP CHANGE FROM FEMA TO CHANGE THE |
| BASE FLOOD ELEVATIONS, CHANGE FLOODWAY BOUNDARIES, OR |
| CHANGE BOUNDARIES OF FLOOD HAZARD AREAS SHOWN ON FIRMS, |
| AND TO SUBMIT SUCH DATA TO FEMA FOR SUCH PURPOSES. THE |
| ANALYSES SHALL BE PREPARED BY A FLORIDA LICENSED |
| ENGINEER IN A FORMAT REQUIRED BY FEMA. SUBMITTAL |
| REQUIREMENTS AND PROCESSING FEES SHALL BE THE |
| RESPONSIBILITY OF THE APPLICANT. |
| |
| SEC. 18-296. - OTHER DEVELOPMENT. |
| (A) |
| GENERAL REQUIREMENTS FOR OTHER DEVELOPMENT . ALL |
| DEVELOPMENT, INCLUDING MAN-MADE CHANGES TO IMPROVED OR |
| UNIMPROVED REAL ESTATE FOR WHICH SPECIFIC PROVISIONS |
| ARE NOT SPECIFIED IN THIS ARTICLE OR THE FLORIDA |
| BUILDING CODE, SHALL: |
| (1) |
| BE LOCATED AND CONSTRUCTED TO MINIMIZE FLOOD DAMAGE; |
| (2) |
| MEET THE LIMITATIONS OF SUBSECTION 18-292(D) OF THIS |
| ARTICLE IF LOCATED IN A REGULATED FLOODWAY; |
| (3) |
| BE ANCHORED TO PREVENT FLOTATION, COLLAPSE OR LATERAL |
| MOVEMENT RESULTING FROM HYDROSTATIC LOADS, INCLUDING |
| THE EFFECTS OF BUOYANCY, DURING CONDITIONS OF THE |
| DESIGN FLOOD; |
| (4) |
| BE CONSTRUCTED OF FLOOD DAMAGE-RESISTANT MATERIALS; AND |
| (5) |
| HAVE MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS ABOVE |
| THE DESIGN FLOOD ELEVATION OR MEET THE REQUIREMENTS OF |
| ASCE 24, EXCEPT THAT MINIMUM ELECTRIC SERVICE REQUIRED |
| TO ADDRESS LIFE SAFETY AND ELECTRIC CODE REQUIREMENTS |
| IS PERMITTED BELOW THE DESIGN FLOOD ELEVATION PROVIDED |
| IT CONFORMS TO THE PROVISIONS OF THE ELECTRICAL PART OF |
| BUILDING CODE FOR WET LOCATIONS. |
| (B) |
| FENCES IN REGULATED FLOODWAYS . FENCES IN REGULATED |
| FLOODWAYS THAT HAVE THE POTENTIAL TO BLOCK THE PASSAGE |
| OF FLOODWATERS, SUCH AS STOCKADE FENCES AND WIRE MESH |
| FENCES, SHALL MEET THE LIMITATIONS OF SUBSECTION |
| 18-292(D) OF THIS ARTICLE. |
| (C) |
| RETAINING WALLS, SIDEWALKS AND DRIVEWAYS IN REGULATED |
| FLOODWAYS . RETAINING WALLS AND SIDEWALKS AND DRIVEWAYS |
| THAT INVOLVE THE PLACEMENT OF FILL IN REGULATED |
| FLOODWAYS SHALL MEET THE LIMITATIONS OF SUBSECTION |
| 18-292(D) OF THIS ARTICLE. |
| (D) |
| ROADS AND WATERCOURSE CROSSINGS IN REGULATED FLOODWAYS |
| . ROADS AND WATERCOURSE CROSSINGS, INCLUDING ROADS, |
| BRIDGES, CULVERTS, LOW-WATER CROSSINGS AND SIMILAR |
| MEANS FOR VEHICLES OR PEDESTRIANS TO TRAVEL FROM ONE |
| SIDE OF A WATERCOURSE TO THE OTHER SIDE, THAT ENCROACH |
| INTO REGULATED FLOODWAYS SHALL MEET THE LIMITATIONS OF |
| SUBSECTION 18-292(D) OF THIS ARTICLE. ALTERATION OF A |
| WATERCOURSE THAT IS PART OF A ROAD OR WATERCOURSE |
| CROSSING SHALL MEET THE REQUIREMENTS OF SUBSECTION |
| 18-284(C)(3) OF THIS ARTICLE. |
| (ORD. NO. 4729-17, ? 3, 9-14-2017 |
| |
| FBC CHPT. 16 |
| 1612.1 GENERAL. |
| WITHIN FLOOD HAZARD AREAS AS ESTABLISHED IN SECTION |
| 1612.3, ALL NEW CONSTRUCTION OF BUILDINGS, STRUCTURES |
| AND PORTIONS OF BUILDINGS AND STRUCTURES, INCLUDING |
| SUBSTANTIAL IMPROVEMENT AND RESTORATION OF SUBSTANTIAL |
| DAMAGE TO BUILDINGS AND STRUCTURES, SHALL BE DESIGNED |
| AND CONSTRUCTED TO RESIST THE EFFECTS OF FLOOD HAZARDS |
| AND FLOOD LOADS. FOR BUILDINGS THAT ARE LOCATED IN MORE |
| THAN ONE FLOOD HAZARD AREA, THE PROVISIONS ASSOCIATED |
| WITH THE MOST RESTRICTIVE FLOOD HAZARD AREA SHALL |
| APPLY. |
| |
| 1612.4 DESIGN AND CONSTRUCTION. |
| THE DESIGN AND CONSTRUCTION OF BUILDINGS AND STRUCTURES |
| LOCATED IN FLOOD HAZARD AREAS, INCLUDING COASTAL HIGH |
| HAZARD AREAS, SHALL BE IN ACCORDANCE WITH CHAPTER 5 OF |
| ASCE 7 AND WITH ASCE 24. |
| |
| |
| |
2018-04-09 08:14:06 | VALUE ADJUSTED PER CONTRACTS. MAT'L. $13,400 + LABOR |
| $3,800 = $17,200. |
| SIGN IS LOCATED IN FLOOD ZONE AE WITH A BFE OF 14 FEET |
| NAVD. CT |