Plan Review Notes
Plan Review Notes For Permit 18030165
Permit Number 18030165
Review Stop B
Sequence Number 1
Notes
Date Text
2018-03-12 17:37:10BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE COPY OF APPROVAL LETTER FROM ARMY CORP OF
 ENGINEER'S.
 2. SUBMITTED SURVEY IS NOT VALID UNLESS SEALED WITH AN
 EMBOSSED SURVEYORS SEAL. (SEE NOTE # 3)
 3. DATE OF BOAT SHOW ON SURVEY STATES MARCH 22, 2017
 THRU MARCH 25, 2018. PLEASE CLARIFY.
 4. APPLICANT SHALL COMPLY WITH THE REQUIREMENTS OF FBC
 CHPT. 31, SECTION 3103 TEMPORARY STRUCTURES.
  
 SECTION3103
 TEMPORARY STRUCTURES
  
 3103.1 GENERAL.
 THE PROVISIONS OF SECTIONS 3103.1 THROUGH 3103.4 SHALL
 APPLY TO STRUCTURES ERECTED FOR A PERIOD OF LESS THAN
 180 DAYS. TENTS AND OTHER MEMBRANE STRUCTURES ERECTED
 FOR A PERIOD OF LESS THAN 180 DAYS SHALL COMPLY WITH
 THE FLORIDA FIRE PREVENTION CODE. THOSE ERECTED FOR A
 LONGER PERIOD OF TIME SHALL COMPLY WITH APPLICABLE
 SECTIONS OF THIS CODE.
  
 3103.1.1 CONFORMANCE.
 TEMPORARY STRUCTURES AND USES SHALL CONFORM TO THE
 STRUCTURAL STRENGTH, FIRE SAFETY, MEANS OF EGRESS,
 ACCESSIBILITY, LIGHT, VENTILATION AND SANITARY
 REQUIREMENTS OF THIS CODE AS NECESSARY TO ENSURE PUBLIC
 HEALTH, SAFETY AND GENERAL WELFARE.
  
 3103.1.2 PERMIT REQUIRED.
 TEMPORARY STRUCTURES THAT COVER AN AREA GREATER THAN
 120 SQUARE FEET (11.16 M2), INCLUDING CONNECTING AREAS
 OR SPACES WITH A COMMON MEANS OF EGRESS OR ENTRANCE
 THAT ARE USED OR INTENDED TO BE USED FOR THE GATHERING
 TOGETHER OF 10 OR MORE PERSONS, SHALL NOT BE ERECTED,
 OPERATED OR MAINTAINED FOR ANY PURPOSE WITHOUT
 OBTAINING A PERMIT FROM THE BUILDING OFFICIAL.
  
 3103.2 CONSTRUCTION DOCUMENTS.
 A PERMIT APPLICATION AND CONSTRUCTION DOCUMENTS SHALL
 BE SUBMITTED FOR EACH INSTALLATION OF A TEMPORARY
 STRUCTURE. THE CONSTRUCTION DOCUMENTS SHALL INCLUDE A
 SITE PLAN INDICATING THE LOCATION OF THE TEMPORARY
 STRUCTURE AND INFORMATION DELINEATING THE MEANS OF
 EGRESS AND THE OCCUPANT LOAD.
  
 3103.3 LOCATION.
 TEMPORARY STRUCTURES SHALL BE LOCATED IN ACCORDANCE
 WITH THE REQUIREMENTS OF TABLE 602 BASED ON THE
 FIRE-RESISTANCE RATING OF THE EXTERIOR WALLS FOR THE
 PROPOSED TYPE OF CONSTRUCTION.
  
 3103.4 MEANS OF EGRESS.
 TEMPORARY STRUCTURES SHALL CONFORM TO THE MEANS OF
 EGRESS REQUIREMENTS OF CHAPTER 10 AND SHALL HAVE AN
 EXIT ACCESS TRAVEL DISTANCE OF 100 FEET (30 480 MM) OR
 LESS
  