2018-03-16 08:17:35 | 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 18030077 |
| ADD: 4106 BROADWAY SUITE: 4104 |
| CONT: ACTION MECHANICAL CONTRACTORS INC. |
| TEL: 561-642-4730 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: THURS. MARCH 15/ 2018 |
| ACTION: DENIED |
| |
| 1)SHEET A1. PLEASE UPDATE THE CODE FROM THE 2014 FBC TO |
| THE 2017 FBC. PLEASE NOTE ON DEC. 31 / 2017 THE 2017 |
| FLORIDA BUILDING CODE WERE ADOPTED STATEWIDE. |
| |
| 2) SHEET A1. PLEASE CORRECT THE OCCUPANCY TYPE THIS IS |
| NOT A A2 OCCUPANCY, THERE WOULD NEED TO BE A MINIMUM OF |
| 50 OCCUPANTS IN A RESTAURANT. THE TENANT SPACE IS A |
| CHANGE IN USE BUT STILL A MERCANTILE OCCUPANCY. FBC-B |
| 309.1 MERCANTILE GROUP M OCCUPANCY INCLUDES, AMONG |
| OTHERS, THE USE OF A BUILDING OR STRUCTURE OR A PORTION |
| THEREOF FOR THE DISPLAY AND SALE OF MERCHANDISE, AND |
| INVOLVES STOCKS OF GOODS, WARES OR MERCHANDISE |
| INCIDENTAL TO SUCH PURPOSES AND ACCESSIBLE TO THE |
| PUBLIC. |
| |
| 3) THE WORK INVOLVED IN THIS CHANGE IN USE WILL REQUIRE |
| A BUILDING PERMIT AS WELL AS THE MECHANICAL PERMIT. |
| EITHER A BUILDING CONTRACTOR OR GENERAL CONTRACTOR WILL |
| BE REQUIRED TO SIGN ONTO A BUILDING PERMIT. F. S. |
| 489.105 DEFINITIONS, GENERAL CONTRACTOR OR BUILDING |
| CONTRACTOR. F. S. 489.113 QUALIFICATIONS FOR PRACTICE; |
| RESTRICTIONS. |
| |
| 4) PLEASE NOTE THE WORK BEING COMPLETED UNDER THIS |
| PERMIT AND PERMIT 17030415 (GAS) IS CREATING A CHANGE |
| IN USE, A COMMERCIAL KITCHEN AND WILL NEED TO SHOW |
| COMPLIANCE WITH THE: |
| |
| 2017 FLORIDA EXISTING BUILDING CODE SECTION 1001.2.1 |
| CHANGE OF USE. ANY WORK UNDERTAKEN IN CONNECTION WITH A |
| CHANGE IN USE THAT DOES NOT INVOLVE A CHANGE OF |
| OCCUPANCY CLASSIFICATION OR A CHANGE TO ANOTHER GROUP |
| WITHIN AN OCCUPANCY CLASSIFICATION SHALL CONFORM TO THE |
| APPLICABLE REQUIREMENTS FOR THE WORK AS CLASSIFIED IN |
| CHAPTER 5 AND TO THE REQUIREMENTS OF SECTIONS 1002 |
| THROUGH 1011. |
| |
| 1010.1 EXIST. BLDG CODE. 1010.1. WHERE THE OCCUPANCY OF |
| AN EXISTING BUILDING OR PART OF AN EXISTING BUILDING IS |
| CHANGED SUCH THAT THE NEW OCCUPANCY IS SUBJECT TO |
| DIFFERENT PLUMBING FIXTURE REQUIREMENTS IN ACCORDANCE |
| WITH THE FLORIDA BUILDING CODE, PLUMBING, THE NEW |
| OCCUPANCY SHALL COMPLY WITH THE INTENT OF THE |
| RESPECTIVE FLORIDA BUILDING CODE, PLUMBING PROVISIONS. |
| |
| 2017 FBC-B 2902.3.6 PROHIBITED TOILET ROOM LOCATION. |
| TOILET ROOMS SHALL NOT OPEN DIRECTLY INTO A ROOM USED |
| FOR THE PREPARATION OF FOOD FOR SERVICE TO THE PUBLIC. |
| |
| 5) THE 2ND PROBLEM WITH THE LOCATION WITH THE EXISTING |
| LOCATION OF THE RESTROOM IN A COMMERCIAL KITCHEN IS THE |
| OCCUPANTS CANNOT GO THROUGH THE KITCHEN TO GAIN ENTRY |
| OF THE RESTROOM. 2017 FBC-B 1016.2 EGRESS THROUGH |
| INTERVENING SPACES. EGRESS THROUGH INTERVENING SPACES |
| SHALL COMPLY WITH THIS SECTION. (5.) EGRESS SHALL NOT |
| PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES |
| USED FOR SIMILAR PURPOSES. |
| |
| 6) SHEET M2 SHOWS A NEW ROOF TOP 3 TON A/C UNIT AND A |
| NEW ROOF EXHAUST FAN. THE ARCHITECTURAL SHEET NOR THE |
| MECHANICAL SHEETS SHOW THE TYPE OF ROOF FRAMING SYSTEM |
| IS WITHIN THIS TENANT SPACE NOR HOW THE PENETRATION |
| THROUGH THE ROOF DECK WILL BE MADE NOR THE REQUIRED |
| EXTRA FRAMING AROUND THE NEW PENETRATION, IF EXTRA |
| FRAMING MEMBERS WILL BE REQUIRED, NOR THE TYPE OF ROOF |
| CURB, AND THE ANCHORING OF THE ROOF CURB TO THE ROOF |
| FRAMING MEMBERS. |
| |
| LATERAL FORCE-RESISTING SYSTEM. FOR ALL ROOF TOP |
| EQUIPMENT, CURBS, FANS OR A/C STANDS, AND OR VENTS, |
| DETAILED ATTACHMENT TO THE ROOF FRAMING & DECK AS WELL |
| AS FROM THE CURB OR ROOF STAND TO THE EQUIPMENT ABOVE. |
| |
| 2017 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL |
| MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY |
| METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT |
| EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY |
| AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. |
| EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE |
| OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES |
| SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND |
| LOADS. |
| |
| 7) PLEASE PROVIDE THE WIND DESIGN CRITERIA FOR THE ROOF |
| TOP UNIT. |
| |
| 2017 FBC-B 1603.1.4 WIND DESIGN DATA. |
| THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL |
| BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE |
| STRUCTURE: |
| |
| 7.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), |
| MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, |
| VASD, AS DETERMINED IN ACCORDANCE WITH SECTION |
| 1609.3.1. |
| |
| 7.2. RISK CATEGORY. |
| |
| 7.HEIGHT AND EXPOSURE. |
| |
| 7.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. |
| |
| 7.DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL |
| RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF. |
| TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & |
| EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE |
| BUILDING. |
| 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. |
| |
| 8) 2014 / 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, |
| RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS |
| OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| APPROVALS: |
| (31(D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS |
| OR VENTILATORS (NOT REVIEWED BY THE DESIGNER OF RECORD, |
| SHOP DRAWING STAMP OF APPROVAL). |
| |
| 9) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC.. |
| |
| 10) PLEASE BE AWARE WITH THE MOVING OF THE RESTROOM |
| FROM BEING IN THE KITCHEN PLEASE KEEP IN MIND THE NEW |
| RESTROOM WILL NEED TO MEET ALL OF THE RESTROOM |
| REQUIREMENTS OF THE 2017 FBC-ACCESSIBILITY CODE IN |
| CHAPTER 6. |
| |
| 11) PLEASE ALSO BE AWARE THAT YOU WILL NEED TO DECLARE |
| COMPLIANCE WITH DISPROPORTIONATE COST OF THE: |
| |
| 2017 ACCESSIBILITY CODE. 202.4.1 DISPROPORTIONATE COST. |
| ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF |
| TRAVEL TO THE ALTERED AREA WILL BE DEEMED |
| DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE |
| COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE |
| PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS |
| EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF |
| TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING |
| AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE |
| ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING |
| RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS, |
| ENLARGING TOILET STALLS, INSULATING PIPES, OR |
| INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS |
| ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH |
| AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, |
| INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT |
| TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING |
| AN INACCESSIBLE DRINKING FOUNTAIN. |
| |
| 12) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS ST. |
| WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| DEVELOPMENT SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |
| |