2018-10-04 16:59:26 | RESIDENTIAL (R2) ALTERATION, FOURTH BUILDING REVIEW |
| CHECKLIST. |
| CODE: FBC 6TH EDITION (2017). |
| |
| 1) THE OWNER OR OWNER'S LEGALLY AUTHORIZED AGENT NEED |
| TO CERTIFY AT THE BOTTOM OF THE ENERGY CALCULATIONS |
| PRIOR TO RECEIVING THE PERMIT AS REQUIRED BY SEC. |
| R103.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| 2) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| FLOOR/CEILING ASSEMBLY FOR TENANT SEPARATION WITH THE |
| APT ON THE SECOND FLOOR. NOTE: TENANT SEPARATION WALL |
| DETAIL "F" ON SHEET S1A DOESN'T PROVIDE SPECIFICATIONS |
| FOR APPROVED HORIZONTAL ASSEMBLY. IT ONLY SPECIFIES THE |
| WALL ASSEMBLY UL-U311. PROVIDE COMPLETE DETAILS AND |
| SPECIFICATIONS FOR APPROVED HORIZONTAL FIRE RATED |
| ASSEMBLY AS REQUIRED . SEC. 420.3 FBC. |
| |
| RESPONSE: |
| NEW DETAIL "G" ON SHEET S1A: |
| A) THE TIME ASSIGNED FOR WOOD JOISTS IS 10 MINUTES NOT |
| 20 MINUTES. SEE TABLE 722.6.2(2). REVISE AS REQUIRED. |
| NOTE: KEEP IN MIND THAT NEED TO GET 1 HOUR FIRE RATED |
| HORIZONTAL ASSEMBLY. NEED TO REVISE ASSEMBLY TO MEET |
| THE ONE HOUR FIRE RATING. |
| |
| B) PROVIDE COMPLETE SPECIFICATIONS FOR THE FLOOR |
| ASSEMBLY SUB FLOORING AND FINISH FLOOR AS REQUIRED BY |
| SEC. 722.6.2.4. FBC. |
| |
| C) PROVIDE COMPLETE SPECIFICATIONS FOR THE ADDITIONAL |
| PROTECTION OF THE FLOOR ASSEMBLY AS REQUIRED BY SEC. |
| 722.6.2.4. FBC. |
| |
| D) PROVIDE COMPLETE SPECIFICATIONS FOR THE FASTENING OF |
| THE FLOOR ASSEMBLY FRAMING MEMBERS AND MEMBRANES |
| (PLYWOOD, GYPSUM BOARD ETC) AS REQUIRED BY SEC. |
| 722.6.2.6 FBC. |
| |
| E) THERE IS A FIRE NOTE ABOVE NEW DETAIL "G" THAT |
| SPECIFIES 2 LAYERS OF 1/2" TYPE X GYPSUM BOARD. |
| COORDINATE THIS INFORMATION WITH DETAIL G AND ALL WALL |
| SECTIONS TO AVOID CONFUSION/DISCREPANCIES. SEC. 107.2.1 |
| CITY AMENDMENTS. |
| |
| 3) INFORMATION ON DRAWINGS NEED TO BE COORDINATED. |
| INFORMATION ON TENANT SEPARATION HORIZONTAL ASSEMBLY |
| DETAIL "G" NEEDS TO BE COORDINATED WITH CEILING |
| INFORMATION ON ALL WALL SECTION DETAILS SHOWN ON SHEET |
| S1 AND SHEET S1A. REVISE AS REQUIRED TO MATCH. SEC. |
| 107.2.1 CITY AMENDMENTS. |
| |
| 4) CEILING INFORMATION UNDER THE EXISTING STAIRS DETAIL |
| ON SHEET S1 WAS REVISED. PREVIOUS DETAIL SPECIFIED 2 |
| LAYERS OF 5/8" FIRE RATED GYPSUM BOARD. NEW DETAIL |
| SPECIFIES ONLY ONE LAYER. CLARIFY/REVISE AS REQUIRED. |
| NEED TO PROVIDE ONE HOUR FIRE RATED TENANT SEPARATION |
| ASSEMBLY WITH THE ABOVE UNIT. SEC. 420.3 FBC. |
| COORDINATE WITH ITEM #2 ABOVE. |
| |
| 5) ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, |
| AND SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING AS REQUIRED BY SEC. |
| 801.3 FBC-EXISTING BUILDING. SHOW COMPLIANCE WITH THE |
| SOUND TRANSMISSION FOR FLOOR/CEILING ASSEMBLY. |
| FLOORING UNDERLAYMENT |
| SOUND INSULATION MATERIAL: |
| A) PROVIDE 2 COPIES OF THE FLAME SPREAD INDEX AND SMOKE |
| DEVELOPED INDEX TEST DONE IN ACCORDANCE WITH ASTM E 84 |
| OR UL 723 AS REQUIRED BY SEC. 720.1 OF FBC 6TH EDITION |
| (2017). |
| |
| B) PROVIDE 2 COPIES OF THE SOUND TRANSMISSION CLASS |
| (STC) TEST DONE IN ACCORDANCE WITH ASTM E 90 AS |
| REQUIRED BY SEC. 1207.2 OF FBC 6TH EDITION (2017). |
| |
| C) PROVIDE 2 COPIES OF THE IMPACT INSULATION CLASS |
| (IIC) TEST DONE IN ACCORDANCE WITH ASTM E 492 AS |
| REQUIRED BY SEC. 1207.3 OF FBC 6TH EDITION (2017). |
| |
| RESPONSE: |
| ICC EVALUATION REPORT ESR-2540 SUBMITTED IS FOR 2X10 |
| WOOD JOIST FLOOR ASSEMBLIES. THIS DOESN'T MATCH |
| EXISTING FLOOR FRAMING. PROVIDE COMPLIANCE WITH THE |
| ABOVE A, B AND C SOUND INSULATION REQUIREMENTS. |
| NOTE: COORDINATE WITH HORIZONTAL TENANT ASSEMBLY DETAIL |
| G TO AVOID CONFLICTS/DELAYS. |
| |
| |
| 6) PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| FAC 61G20-3.001 FOR: |
| NOTE: THIS MAY BE SUBMITTED LATER AS DEFERRED |
| SUBMITTAL, BUT BEFORE INSTALLATION (NO FEES). |
| |
| A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY |
| IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE |
| DESIGN PRESSURES OF SEC. 1609 FBC. NOTE: IF THE |
| SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES FOR |
| ALL ROOF ZONES, THEN SIGNED AND SEALED RAS 117 |
| CALCULATIONS ARE REQUIRED. |
| |
| RESPONSE: |
| NO PRODUCT APPROVAL WAS SUBMITTED. NEED PRODUCT |
| APPROVAL AND SPECIFIC ASSEMBLY TO BE INSTALLED. |
| |
| B) ROOF TILE ADHESIVE REFERENCED IN ROOF TILE NOA |
| 15-0915.09 SUBMITTED. ROOF TILE ADHESIVE RTA-1 |
| SUBMITTED IS NOT THE ONE REFERENCED IN THE NOA FOR CLAY |
| TILE. AND, CLEARLY MARK PADDY SIZE. |
| |
| 7- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS |
| REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| |
| 8) PROVIDE COMPLETE INFORMATION FOR THE FIRE RATING |
| ASSEMBLY BELOW THE STAIRS AND BY THE PANTRY CLOSET ON |
| FIRST FLOOR KITCHEN. SEC. 420.2 AND 420.3 FBC. |
| |
| RESPONSE: |
| SPECIFIED ASSEMBLY DOESN'T PROVIDE 1 HOUR FIRE RATED |
| ASSEMBLY. COORDINATE WITH ITEM #4 ABOVE. |
| |
| |
| ARCHITECTS-ENGINEERS |
| FLORIDA STATUTE 553.80(2)(B): |
| WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? |
| DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN |
| ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING |
| CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS |
| REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO |
| CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY |
| NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, |
| EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, |
| ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, |
| MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER |
| REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING |
| COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL |
| GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH |
| REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, |
| A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE |
| PERMIT FEE ATTRIBUTED TO PLANS REVIEW |
| |
| NOTE: |
| ENGINEER OF RECORD TO PROVIDE RESPONSE LETTER |
| ADDRESSING EACH COMMENT TO AVOID PLAN REVIEW FEES AS |
| REQUIRED BY FLORIDA STATUTE 553.80(2)(B). |
| |
| ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY |
| REVIEWED DRAWINGS. DON'T STAPLE OLD DRAWINGS TO PLANS. |
| |