Plan Review Notes
Plan Review Notes For Permit 18020917
Permit Number 18020917
Review Stop B
Sequence Number 1
Notes
Date Text
2018-03-13 10:32:151ST REVIEW: FBC 2017 5TH EDITION
 1ST REVIEW FBC 2017 EXISTING BUILDING
  
 FAILED.
  
 1) PLEASE PROVIDE CLEAR PLANS REGARDING THE ALTERATION
 TO ELECTRICAL AND BATHROOM KITCHEN REMODELING. IS THERE
 TO BE A SHOWER PAN REPLACEMENT? CONTRACT INDICATES SO.
 IF SO PROVIDE DETAIL. WIL THE KITCHEN CABINETS BE
 ALTERED OR IS THE ARRANGEMENT TO BE THE SAME? DRAWINGS
 ARE TO BE SIGNED BY THE PERSON RESPONSIBLE. THE
 ELECTRICIAN, PLUMBER, AND OR BUILDING CONTRACTOR MY
 DEVELOP DESIGN DOCUMENTS, BUT SUCH PERSON MUST INDICATE
 LICENSE NUMBER IF APPLICABLE, PRINT NAME, AND SIGN THE
 DESIGN.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 2) THE PLUMBING PLAN REVIEW REQUESTS DEMONSTRATION OF
 COMPLIANCE WITH FAIR HOUSING. PLEASE BE ADVISED OF THE
 APPLICABILITY WHICH YOU MAY DETERMINE AT THE WEB
 ADDRESS BELOW.
  
 HTTPS://CODES.ICCSAFE.ORG/PUBLIC/DOCUMENT/FAC2017/FAIR-
 HOUSING-ACCESSIBILITY-GUIDELINES-DESIGN-GUIDELINES-FOR-
 ACCESSIBLE-ADAPTABLE-DWELLINGS
  
 3) FLOORING - THE SOUND INSULATION PRODUCT DATA SHEET
 PROVIDED IS INSUFFICIENT AS A SUBMITTAL TO DEMONSTRATE
 COMPLIANCE WITH:
 FBC 603.1 FLAME SPREAD; INSULATION BETWEEN A FINISHED
 FLOOR AND SOLID DECKING W/O AN INTERVENING SPACE
 W/FLAME SPREAD INDEX OF 200 OR LESS.
 FBC 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 THIS PRODUCT IS FOR USE WITH WOOD FLOORS, NOT TILE.
 PROVIDE TEST REPORTS FROM A THIRD PARTY TESTING AGENCY
 FOR A SOUND INSULATION PRODUCT TO DEMONSTRATE
 COMPLIANCE WITH THE ABOVE CRITERIA. IT MUST BE
 CONSISTENT WITH THE PROPOSED INSTALLATION AND THE
 ASSEMBLY OF THE FLOOR CEILING ASSEMBLY IN PLACE AT THE
 BUILDING. THIS IS A 6" OR 8" FLOOR CEILING SLAB WITH NO
 SUSPENDED CEILING BELOW. YOU MAY VERIFY VIA PUBLIC
 RECORDS REQUEST OR PERHAPS THE BUILDING MANAGEMENT CAN
 PROVIDE THE DATA TO YOU.
  
  
 STEVEN KENNEDY, CBO
 ASSISTANT BUILDING OFFICIAL
 (561) 805-6710
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved