Date |
Text |
2018-02-27 11:16:05 | BUILDING PLAN REVIEW |
| 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER, PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| 1ST REVIEW |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. DESIGN WIND LOADS BASED ON ASCE 7-10 ARE VALID, BUT |
| PLANS ARE BASED ON THE 2014 FBC. THE CURRENT GOVERNING |
| CODE IS THE 2017 FBC 6TH ED. PLEASE CORRECT CODE |
| REFERENCE ON PLANS. |
| 2. ENGINEER OF RECORD TO SIGN AND SEAL ALL PLAN AGES. |
| 3. PROVIDE FLAME SPREAD REPORT FOR AWNING FABRIC PER |
| ASTM E-84 OR NFPA 701. |
| 4. PROVIDE SITE PLAN. SHOW LOCATION OF ALL WORK. |
| 5. PROVIDE DETAIL OF EXISTING OR PROPOSED FOUNDATION. |
| |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE 2017 |
| FLORIDA BUILDING CODE, 6TH EDITION. |
| |
| PURSUANT TO FBC 107.1, AND FS 481.229 (1) I, AS THIS |
| DESIGN EXCEEDS $25,000.00 IN VALUE, THE DESIGN MUST BE |
| PREPARED BY A LICENSED PROFESSIONAL PURSUANT TO FS 481. |
| SEE BELOW: |
| |
| PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND |
| SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, |
| DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE |
| 61G15-23.001. |
| |
| FBC 603.1 FLAME SPREAD ? ASTM E-84-09 |
| |
| FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING |
| OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA |
| AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION |
| PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL |
| FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING |
| DIMENSIONS; AND ALL EXTERIOR ELEVATIONS: |
| |
| 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| CONSTRUCTION DOCUMENTS SHALL BE |
| DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. |
| CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| OFFICIAL. |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |