Date |
Text |
2018-03-05 16:37:36 | 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 18020402 |
| ADD: 2901 OKEECHOBEE BLVD. |
| CONT: HEDRICK BROTHERS |
| TEL: 561-360-3817 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 1ST REVIEW |
| DATE: MON. MARCH 05/ 2018 |
| ACTION: DENIED |
| |
| 1) THE COVERSHEET OF THE ARCHITECTURAL PLANS IS DATED |
| 12/18/2017 IN THE ARCHITECTURAL SHEETS THERE IS NO |
| REFERENCE TO WHAT PLANS THEY WERE DEVELOPED. IN THE |
| STRUCTURAL SHEETS, SHEET S13.0.1 UNDER THE HEADING |
| STRUCTURAL SPECIFICATIONS / MISCELLANEOUS NOTE # 4 |
| INDICATES THE APPLICABLE BUILDING CODE: 5TH EDITION |
| (2014) FLORIDA BUILDING CODE. |
| THE 6TH EDITION (2017) FLORIDA WAS ADOPTED STATEWIDE ON |
| DEC. 31/ 2017. PLEASE UPDATE THE PLANS TO THE |
| APPLICABLE CODE. |
| |
| 2) 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR |
| BUILDINGS: |
| 107.3.5.1 COMMERCIAL BUILDINGS: |
| 107.3.5.1.1 BUILDING |
| 2.1. OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS |
| SHALL BE DETERMINED. |
| 2.2. MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED |
| (SEE TABLE 506.2). |
| |
| 3) MISSING THE SOILS REPORT. THE STRUCTURAL SHEET |
| S13.0.1. UNDER THE HEADING SITE WORK NOTE # 1 INDICATES |
| A SUBSURFACE INVESTIGATION HAS BEEN COMPLETED BY |
| ARDAMAN & ASSOCIATES REPORT DATED MAY 07/ 2015, WHICH |
| IS AN INTEGRAL PART OF THESE CONTRACT DOCUMENTS. 2017 |
| FBC-B SECTION 1803.5.2 QUESTIONABLE SOIL. |
| |
| 4A) THE ARCHITECTURAL PLAN A13.4.0 INDICATES THE FINISH |
| ROOFING SYSTEM IS TO BE TPO ROOFING SYSTEM. PLEASE |
| PROVIDE THE PRODUCT APPROVAL REPORT FOR THIS PRODUCT. / |
| 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, |
| RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS |
| OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| APPROVALS: |
| (31) (D) ROOFING PRODUCTS AND ASSEMBLIES, |
| |
| 4B) FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL |
| ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR |
| ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, |
| IF ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. |
| FASTENER DENSITIES SHALL BE INCREASED FOR BOTH |
| INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE |
| WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION |
| PREPARED, SIGNED AND |
| SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR |
| REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS & |
| CLADDING. |
| |
| 4C) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE |
| PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 |
| SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL. |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC.. |
| |
| 5) SHEET S13.0.2. SHOWS A MONO-SLOPED ROOF WITH NO |
| PARAPETS. PRESSURES ARE THE SAME FOR ZONE 2 AND 3 |
| PLEASE PROVIDE WHY THE NEGATIVE ROOF PRESSURES HAVE NOT |
| BEEN INCREASED. THE MONO- SLOPED ROOF DETAIL EVEN SHOWS |
| (4) ROOF ZONE 3?S. ASCE 7-10 FIGURE 30.4-5A. PLEASE |
| UPDATE PLANS. |
| |
| 6) BUILDING PROVISO: PRECAST PLANK JOIST SYSTEMS ARE TO |
| BE A DEFERRED SUBMITTAL AND TO BE REVIEWED BY THE |
| DESIGNER OF RECORD, WHEN APPROVED THE ARCHITECTS SHOP |
| DRAWING STAMP OF APPROVAL APPLIED AND FORWARDED TO THE |
| BUILDING DEPARTMENT. |
| |
| 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS ST. |
| WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |
| |
| |
| |
| |
| |
| |