Plan Review Notes For Permit 18020327 |
Permit Number |
18020327 |
|
Review Stop |
P |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2018-04-24 17:54:25 | 04/24/2018 2ND PLUMBING REVIEW**DENIED** | | | | PLEASE BE ADVISED THE NEW SET OF PLANS ARE SHOWING THIS | | AS THE ONLY BATHROOM AND THE 1ST SET OF PLANS SUBMITTED | | DO NOT HAVE THE CORRECT ADDRESS ON THEM. THIS BUILDING | | BUILT IN 2005 UNDER PERMIT # 03020961 WAS BUILT | | COMPLING WITH THE FAIR HOUSING DESIGN MANUAL WITH SPEC | | A BATHROOM WHICH MUST FULLY REMAIN. | | | | | | 1) A SHOWER INSTALLED ADJACENT TO A TOILET IS NOT | | ACCEPTABLE UNDER THE GUIDELINES ( FAIR HOUSING MANUAL | | 7.44) | | | | 2) SHOWER VALVE IS NOT IN A ACCESSIBLE LOCATION TO BE | | ACCESSED FROM THE CLEAR FLOOR SPACE AREA. | | | | 3) WHERE A SHOWER IS THE ONLY BATHING FIXTURE IN A | | DWELLING IT MUST COMPLY WITH ( FAIR HOUSING MANUAL 7.58 | | | | 4) SHOW CABINET DETAIL. MAX COUNTER TOP TO SINK IS 34". | | ( FAIR HOUSING MANUAL 7.52 | | | | 5) SHOW ALL REQUIRED CLEAR FLOOR SPACES. ( FAIR HOUSING | | MANUAL 7.43) | | | | 6) TOILETS ARE REQUIRED TO BE 18" MIN ON GRAB BAR SIDE | | AND 15" ON NONE GRAB BAR SIDE TOTAL MIN 33". ( FAIR | | HOUSING MANUAL 7.43) | | | | 7) EXISTING DRAIN OFFSET TO BE 30" MAX FROM CENTERLINE | | OF TRAP. FBC-P 1002.1 | | | | | | TIM HUNT | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | 561-805-6695 | | [email protected] | | |
|