Plan Review Notes
Plan Review Notes For Permit 18020254
Permit Number 18020254
Review Stop B
Sequence Number 4
Notes
Date Text
2018-05-16 17:54:52APPROVED WITH EXCEPTIONS AND PROVISOS.
  
 1) ON SHEET 067-A-305 SECTION 2/A-3.05, THE 12"
 HORIZONTAL HANDRAIL EXTENSION IS REQUIRED TO RETURN TO
 A WALL, GUARD OR THE LANDING AT THE BOTTOM OF THE RAMP
 PER FBC ACCESSIBILITY SECTION 505.10.1.
  
 2) PROVISO/ DEFERRED SUBMITTAL. SUBMIT TWO SETS OF
 MANUFACTURER'S SPECIFICATIONS AND LISTING INFORMATION
 FOR REVIEW FOR THE LULA LIFT AT THE ENTRY PORT COCHERE.
  
 3) PROVISO/ DEFERRED SUBMITTAL. SHEET A104-A-601 DOOR
 STYLE 20 IS A SLIDING BARN DOOR AND TRACK SYSTEM,
 HARDWARE GROUP 11 INDICATES ADA COMPLIANT PULLS. THE
 DOOR HAS TO MAINTAIN A 32 INCH CLEAR OPENING AS WELL AS
 THE HARDWARE MEET COMPLIANCE WITH :
 2017 ACCESS. CODE 404.2.7 DOOR AND GATE HARDWARE.
 HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE
 PARTS ON DOORS AND GATES SHALL COMPLY WITH 309.4.
 OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES
 MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND. WHERE SLIDING DOORS ARE IN THE FULLY OPEN
 POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND
 USABLE FROM BOTH SIDES.
  
 4) PROVISO/ DEFERRED SUBMITTAL. WINDOWS ARE UNDER A
 SEPARATE PERMITS BUT THERE WILL BE OTHER COMPONENTS AND
 CLADDING REQUIREMENTS. 2017 FBC-B 1609.1.2 PROTECTION
 OF OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE
 CODE 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES.
 (C) PANEL WALLS: WALL LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP
 VENTILATORS
 (G) PRE-ENGINEERED A/C STANDS
  
 5) PROVISO/ DEFERRED SUBMITTAL. W. P. B. 107.3.4.1
 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED
 BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE
 ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING
 ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC..
  
 6) SEPARATE PERMITS REQUIRED. THE POOL, GENERATOR,
 KITCHEN HOODS, SUPPRESSION, GAS, FENCES, SIGNS, FIRE
 SPRINKLERS, FIRE ALARMS, LANDSCAPING, IRRIGATION
 PERMITS ARE NOT REVIEWED UNDER THE MAIN BUILDING PERMIT
 AND REQUIRE SEAPARTE PERMITS, PLAN REVIEWS AND FEES.
  
  
  