2018-02-05 12:25:372017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 18020085
 ADD: 6000 N FLAGLER DR. EVENT: MANATEE LAGOON
 CONT: 489 EXEMPT / SARAH MARMION
 TEL: 786-375-0914
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: MON. FEB. 05/2017
 ACTION: DENIED
  
 1) SPECIAL EVENT/ PERMIT APPLICATION MARKED YES FOR
 TENTS. IT IS THE APPLICANTS RESPONSIBILITY TO SECURE
 ALL NECESSARY TENT AND ELECTRICAL PERMITS FROM THE
 DEVELOPMENT SERVICES DEPARTMENT AT LEAST ONE WEEK PRIOR
 TO THE EVENT. FAILURE TO COMPLY WITH THE NECESSARY TIME
 LINE AND SECURING THE NECESSARY TENT PERMIT
 REQUIREMENTS.
 PLEASE SHOW COMPLIANCE WITH THE:
  
 2017 FBC-B/ SECTION3103 / TEMPORARY STRUCTURES
  
 1A) 3103.1 THE PROVISIONS OF SECTIONS 3103.1 THROUGH
 3103.4 SHALL APPLY TO STRUCTURES ERECTED FOR A PERIOD
 OF LESS THAN 180 DAYS. TENTS AND OTHER MEMBRANE
 STRUCTURES ERECTED FOR A PERIOD OF LESS THAN 180 DAYS
 SHALL COMPLY WITH THE FLORIDA FIRE PREVENTION CODE.
 THOSE ERECTED FOR A LONGER PERIOD OF TIME SHALL COMPLY
 WITH APPLICABLE SECTIONS OF THIS CODE.
  
 1B) 3103.1.1 CONFORMANCE. TEMPORARY STRUCTURES AND USES
 SHALL CONFORM TO THE STRUCTURAL STRENGTH, FIRE SAFETY,
 MEANS OF EGRESS, ACCESSIBILITY, LIGHT, VENTILATION AND
 SANITARY REQUIREMENTS OF THIS CODE AS NECESSARY TO
 ENSURE PUBLIC HEALTH, SAFETY AND GENERAL WELFARE.
  
  
 1C) THE SUBMITTED SITE PLAN FAILS TO PROVIDE THE SIZE
 OF EACH TENT AND THE DISTANCE BETWEEN TENTS. 3103.1.2
 PERMIT REQUIRED. TEMPORARY STRUCTURES THAT COVER AN
 AREA GREATER THAN 120 SQUARE FEET (11.16 M2), INCLUDING
 CONNECTING AREAS OR SPACES WITH A COMMON MEANS OF
 EGRESS OR ENTRANCE THAT ARE USED OR INTENDED TO BE USED
 FOR THE GATHERING TOGETHER OF 10 OR MORE PERSONS, SHALL
 NOT BE ERECTED, OPERATED OR MAINTAINED FOR ANY PURPOSE
 WITHOUT OBTAINING A PERMIT FROM THE BUILDING OFFICIAL.
  
  
 1D) 3103.2 CONSTRUCTION DOCUMENTS. A PERMIT APPLICATION
 AND CONSTRUCTION DOCUMENTS SHALL BE SUBMITTED FOR EACH
 INSTALLATION OF A TEMPORARY STRUCTURE. THE CONSTRUCTION
 DOCUMENTS SHALL INCLUDE A SITE PLAN INDICATING THE
 LOCATION OF THE TEMPORARY STRUCTURE AND INFORMATION
 DELINEATING THE MEANS OF EGRESS AND THE OCCUPANT LOAD.
  
  
 1E) 3103.3 LOCATION. TEMPORARY STRUCTURES SHALL BE
 LOCATED IN ACCORDANCE WITH THE REQUIREMENTS OF TABLE
 602 BASED ON THE FIRE-RESISTANCE RATING OF THE EXTERIOR
 WALLS FOR THE PROPOSED TYPE OF CONSTRUCTION.
  
  
 1F) 3103.4 MEANS OF EGRESS. TEMPORARY STRUCTURES SHALL
 CONFORM TO THE MEANS OF EGRESS REQUIREMENTS OF CHAPTER.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  