Date |
Text |
2018-02-05 12:25:37 | 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 18020085 |
| ADD: 6000 N FLAGLER DR. EVENT: MANATEE LAGOON |
| CONT: 489 EXEMPT / SARAH MARMION |
| TEL: 786-375-0914 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 1ST REVIEW |
| DATE: MON. FEB. 05/2017 |
| ACTION: DENIED |
| |
| 1) SPECIAL EVENT/ PERMIT APPLICATION MARKED YES FOR |
| TENTS. IT IS THE APPLICANTS RESPONSIBILITY TO SECURE |
| ALL NECESSARY TENT AND ELECTRICAL PERMITS FROM THE |
| DEVELOPMENT SERVICES DEPARTMENT AT LEAST ONE WEEK PRIOR |
| TO THE EVENT. FAILURE TO COMPLY WITH THE NECESSARY TIME |
| LINE AND SECURING THE NECESSARY TENT PERMIT |
| REQUIREMENTS. |
| PLEASE SHOW COMPLIANCE WITH THE: |
| |
| 2017 FBC-B/ SECTION3103 / TEMPORARY STRUCTURES |
| |
| 1A) 3103.1 THE PROVISIONS OF SECTIONS 3103.1 THROUGH |
| 3103.4 SHALL APPLY TO STRUCTURES ERECTED FOR A PERIOD |
| OF LESS THAN 180 DAYS. TENTS AND OTHER MEMBRANE |
| STRUCTURES ERECTED FOR A PERIOD OF LESS THAN 180 DAYS |
| SHALL COMPLY WITH THE FLORIDA FIRE PREVENTION CODE. |
| THOSE ERECTED FOR A LONGER PERIOD OF TIME SHALL COMPLY |
| WITH APPLICABLE SECTIONS OF THIS CODE. |
| |
| 1B) 3103.1.1 CONFORMANCE. TEMPORARY STRUCTURES AND USES |
| SHALL CONFORM TO THE STRUCTURAL STRENGTH, FIRE SAFETY, |
| MEANS OF EGRESS, ACCESSIBILITY, LIGHT, VENTILATION AND |
| SANITARY REQUIREMENTS OF THIS CODE AS NECESSARY TO |
| ENSURE PUBLIC HEALTH, SAFETY AND GENERAL WELFARE. |
| |
| |
| 1C) THE SUBMITTED SITE PLAN FAILS TO PROVIDE THE SIZE |
| OF EACH TENT AND THE DISTANCE BETWEEN TENTS. 3103.1.2 |
| PERMIT REQUIRED. TEMPORARY STRUCTURES THAT COVER AN |
| AREA GREATER THAN 120 SQUARE FEET (11.16 M2), INCLUDING |
| CONNECTING AREAS OR SPACES WITH A COMMON MEANS OF |
| EGRESS OR ENTRANCE THAT ARE USED OR INTENDED TO BE USED |
| FOR THE GATHERING TOGETHER OF 10 OR MORE PERSONS, SHALL |
| NOT BE ERECTED, OPERATED OR MAINTAINED FOR ANY PURPOSE |
| WITHOUT OBTAINING A PERMIT FROM THE BUILDING OFFICIAL. |
| |
| |
| 1D) 3103.2 CONSTRUCTION DOCUMENTS. A PERMIT APPLICATION |
| AND CONSTRUCTION DOCUMENTS SHALL BE SUBMITTED FOR EACH |
| INSTALLATION OF A TEMPORARY STRUCTURE. THE CONSTRUCTION |
| DOCUMENTS SHALL INCLUDE A SITE PLAN INDICATING THE |
| LOCATION OF THE TEMPORARY STRUCTURE AND INFORMATION |
| DELINEATING THE MEANS OF EGRESS AND THE OCCUPANT LOAD. |
| |
| |
| 1E) 3103.3 LOCATION. TEMPORARY STRUCTURES SHALL BE |
| LOCATED IN ACCORDANCE WITH THE REQUIREMENTS OF TABLE |
| 602 BASED ON THE FIRE-RESISTANCE RATING OF THE EXTERIOR |
| WALLS FOR THE PROPOSED TYPE OF CONSTRUCTION. |
| |
| |
| 1F) 3103.4 MEANS OF EGRESS. TEMPORARY STRUCTURES SHALL |
| CONFORM TO THE MEANS OF EGRESS REQUIREMENTS OF CHAPTER. |
| |
| 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS ST. |
| WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |