2018-02-01 11:21:27 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | REVISION DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE HANDWRITTEN NOTE ON THE REVISED PLANS FOR THE | | DOUBLE 2X6 HEADER OVER THE THREE WINDOWS IN THE DINING | | ROOM IS NOT ACCEPTABLE. THE PLANS ARE SIGNED AND SEALED | | BY A FLORIDA LICENSED ENGINEER AND ONLY THE ENGINEER | | CAN MAKE CHANGES TO THEM. SUBMIT TWO REVISED SETS OF | | PLANS THAT INCLUDES THIS NOTE OR SUBMIT (2) SIGNED AND | | SEALED LETTERS FROM THE ENGINEER THAT IS SPECIFIC TO | | THIS APPLICATION. FS 471 | | | | 2) ON THE REVISED PLAN SHEET S-2.1, THE STUD PLATE TIES | | HAVE BEEN CHANGED TO SP2 USING WHITE OUT AND | | HANDWRITING OVER IT. THIS IS NOT ACCEPTABLE ON DRAWINGS | | THAT HAVE BEEN SIGNED AND SEALED BY AN ENGINEER. SUBMIT | | TWO REVISED SETS OF PLANS THAT INCLUDES THIS NOTE OR | | SUBMIT (2) SIGNED AND SEALED LETTERS FROM THE ENGINEER | | THAT IS SPECIFIC TO THIS APPLICATION. FS 471 | | |
|