Plan Review Notes For Permit 18011087 |
Permit Number |
18011087 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2018-01-31 09:43:51 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | CODE: FBC 6TH EDITION (2017). | | | | 1- WIND LOAD CALCULATIONS SUBMITTED: | | A) NEED TO HAVE THE ENGINEER'S ORIGINAL SEAL AND | | SIGNATURE AS REQUIRED BY CHAPTER 471 FLORIDA STATUTE | | WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS. | | | | B) REVISE THE MINIMUM EDGE DISTANCE. ACCORDING TO | | FOOTNOTE OF FIGURE R301.2(7) FBC-RESIDENTIAL, 6TH | | EDITION (2017) THE MINIMUM EDGE DISTANCE "A" IS 4'-0" | | IN ALL CASES NOT 3'-0". REVISE AS REQUIRED. | | | | 2- REVISE INSTALLATION SCHEDULE SUBMITTED. | | A) THE FASTENER EDGE DISTANCE EXCLUDES THE STUCCO | | FINISH. SEE NOTES ON ANCHOR SCHEDULE TABLE ON SHEET 11 | | OF 13. ADD THE STUCCO THICKNESS AND REVISE INSTALLATION | | SCHEDULE AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | B) SPECIFY LENGTH OF ANCHORS TO VERIFY MINIMUM | | EMBEDMENT REQUIRED ON ANCHOR SCHEDULE TABLE ON SHEET 11 | | OF 13. SEC. 107.2.1 CITY AMENDMENTS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|