Plan Review Notes For Permit 18010784 |
Permit Number |
18010784 |
|
Review Stop |
B |
Sequence Number |
5 |
|
Notes |
Date |
Text |
2018-02-26 18:15:21 | RESIDENTIAL (R3) ALTERATION, FIFTH BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 6TH EDITION (2017). | | | | NOTE; | | FLORIDA PRODUCT APPROVAL FL15413.9 SUBMITTED IS THE | | SAME THAT WAS SUBMITTED ON THE SECOND REVIEW. SEE COPY | | OF COMMENTS BELOW. NEED TO PROVIDE PRODUCT APPROVAL | | THAT MEETS ALL THE CRITERIA FOR ALL HORIZONTAL AND | | VERTICAL MULLIONS BASED ON ALL THE WINDOW SIZES. | | | | | | | | RESIDENTIAL (R3) ALTERATION, SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 6TH EDITION (2017). | | | | 1- WINDOW MULLION PRODUCT APPROVAL FL15413- R5 | | SUBMITTED: ACCORDING TO HORIZONTAL MULLION FL-15413.9 | | THE MAXIMUM WINDOW FRAME HEIGHT IS 54". SEE SHEET 1 OF | | 8 OF DRAWING SUBMITTED. THE DOUBLE HUNG WINDOW SIZE IS | | 61.5". THEREFORE, THIS MULLION SIZE CAN NOT BE USED. | | PROVIDE ANOTHER PRODUCT APPROVAL THAT CAN BE USED. | | FAC 61G20-3.001. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|