2018-01-22 12:19:49 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | CODE: FBC 6TH EDITION (2017). | | | | 1- ENGINEER LETTER SUBMITTED FOR THE ROOF TO WALL | | CONNECTIONS NEED TO BE REVISED. ACCORDING TO SEC. | | R301.2.1.4 FBC-RESIDENTIAL 5TH EDITION (2014) THIS | | BUILDING IS LOCATED IN EXPOSURE "D" NOT EXPOSURE "C". | | REVISE AS REQUIRED OR PROVIDE COMPLETE ENGINEERING | | ANALYSIS. | | | | 2- ROOF TILE ADHESIVE PRODUCT APPROVAL FL6332-R8 | | SUBMITTED: CLEARLY MARK ON THE PRODUCT APPROVAL THE | | PADDY SIZE TO BE INSTALLED TO VERIFY COMPLIANCE WITH | | THE DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: KEEP IN MIND THAT THIS BUILDING IS LOCATED IN | | EXPOSURE "D". COORDINATE WITH ITEM #1 ABOVE. | | | | 3- PROVIDE SKYLIGHT CURRENT PRODUCT APPROVAL. PRODUCT | | APPROVAL FL2418-R9 SUBMITTED IS FOR THE 2014 CODE. THE | | CURRENT CODE IS THE FBC-6TH EDITION (2017). PROVIDE 2 | | COPIES OF CURRENT PRODUCT APPROVAL. FAC 61G20-3.001. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|