2018-04-25 08:26:39 | ****PLAN REVIEW COMMENTS**** |
| |
| ART LANGE BUILDING PLANS EXAMINER |
| |
| DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS STREET |
| WEST PALM BEACH, FL 33402 |
| |
| 561-805-6718 [email protected] |
| |
| |
| DENIED BY BUILDING SECOND REVIEW |
| |
| |
| 1) NOT PROVIDED: PROVIDE A DRAINAGE PLAN SHOWING |
| COMPLIANCE WITH SEC. R401.3 FBC-RESIDENTIAL. |
| |
| PROVIDE TWO SETS OF DRAINAGE PLANS THAT SHOW COMPLIANCE |
| WITH FBC-R401.3 DRAINAGE. SURFACE DRAINAGE SHALL BE |
| DIVERTED TO A STORM SEWER CONVEYANCE OR OTHER APPROVED |
| POINT OF COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS |
| SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM |
| FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 |
| INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048 MM). |
| EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER |
| PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL |
| WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE |
| CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. |
| IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE |
| BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 |
| PERCENT AWAY FROM THE BUILDING. |
| |
| EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER |
| PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL |
| WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE |
| CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. |
| IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE |
| BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 |
| PERCENT AWAY FROM THE BUILDING. |
| |
| 2) PARTIALLY COMPLIED |
| FBC 107.2.5 THE CONSTRUCTION DOCUMENTS SUBMITTED WITH |
| THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY A |
| SITE PLAN SHOWING TO SCALE THE ESTABLISHED STREET |
| GRADES AND THE PROPOSED FINISHED GRADES AND, AS |
| APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN |
| FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE |
| WITH AN ACCURATE BOUNDARY LINE SURVEY. |
| |
| 15) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT |
| A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW |
| COMMENTS HAS BEEN ADDRESSED. |
| |
| RE-SUBMITTAL PROCEDURE |
| YOU ARE REQUIRED TO FILL OUT A RE-SUBMITTAL FORM TO BE |
| SUBMITTED WITH THE CORRECTED PLANS AND/OR OTHER |
| DOCUMENTS. THE PERMIT CLERK WILL RETRIEVE THE DENIED |
| APPLICATION, PLANS AND OTHER DOCUMENTS FOR YOU. YOU ARE |
| REQUIRED TO REMOVE THE OLD PLAN SHEETS THAT HAVE BEEN |
| CORRECTED AND REPLACE THEM WITH THE NEW ONES. THE CLERK |
| WILL PROVIDE YOU WITH A STAPLE REMOVER AND A STAPLER. |
| ONE SET OF THE OLD PLAN SHEETS THAT HAVE BEEN REMOVED |
| SHALL BE MARKED AS VOIDED AND RESUBMITTED ALONG WITH |
| THE TWO (OR MORE) SETS THAT CONTAIN THE CORRECTED |
| SHEETS. IF THERE ARE ANY SHEETS THAT HAVE BEEN STAMPED |
| FOR COUNTY IMPACT FEES, HOA APPROVAL STAMPS OR OTHERS, |
| RESUBMIT THOSE SHEETS. |
| IF ALL OF THE PLAN SHEETS HAVE BEEN CORRECTED, THEN TWO |
| (OR MORE) SETS OF THE NEW PLANS AND ANY OTHER DOCUMENTS |
| SHALL BE SUBMITTED. |
| |
| |
| _______________________________________________________ |
| _________________ |
| |
| DEFERRED SUBMITTALS: |
| |
| THE FOLLOWING ITEMS HAVE BEEN LISTED ON THE COVER SHEET |
| AS DEFERRED SUBMITTALS. |
| WINDOWS |
| ROOFING AND ROOF VENTS, |
| DOORS |
| ALUMINUM RAILINGS |
| PRECAST LINTELS |
| |
| |
| |
| |
| |
| |