Plan Review Notes For Permit 17120840 |
Permit Number |
17120840 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2018-02-22 18:18:32 | APPROVED WITH EXCEPTIONS | | | | SURFACE DRAINAGE SHALL COMPLY WITH FBC-R401.3. SURFACE | | DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE | | OR OTHER APPROVED POINT OF COLLECTION THAT DOES NOT | | CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN SURFACE | | WATER AWAY FROM FOUNDATION WALLS. THE GRADE SHALL FALL | | A MINIMUM OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET | | (3048 MM). | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL | | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE | | CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. | | IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE | | BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 | | PERCENT AWAY FROM THE BUILDING. | | |
|