2018-04-24 09:33:37 | NEW SINGLE FAMILY RESIDENCE (R3), SECOND BUILDING |
| REVIEW CHECKLIST. |
| CODE: FBC 5TH EDITION (2014). |
| |
| 1- BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, |
| ONE SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO |
| PALM BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS |
| WITH THE IMPACT FEE STAMP AND A COPY OF THE PAID |
| RECEIPT MUST BE RETURNED TO THE CITY BUILDING |
| DEPARTMENT BEFORE THE BUILDING PERMIT CAN BE ISSUED. |
| FOR INFORMATION CALL PALM BEACH COUNTY IMPACT FEES AT |
| (561) 233-5025. |
| |
| 2- COMPLIED. |
| |
| 3- SHEET A-1. REVISE THE EGRESS WINDOWS NOTE THAT IS |
| LOCATED BELOW THE WINDOW SCHEDULE: |
| A) COMPLIED. |
| B) COMPLIED. |
| C) COMPLIED. |
| |
| 4- COMPLIED. |
| |
| 5- RESPONSE: NOT ADDRESSED. NOTE: NEED DRAINAGE PLAN. |
| SEE CITY AMENDMENTS SEC. 107.2.5 BELOW. |
| |
| ORIGINAL COMMENT: |
| PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH SEC. |
| R401.3 FBC-RESIDENTIAL. |
| R401.3 DRAINAGE. |
| SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT |
| DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN |
| SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE |
| SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE |
| FIRST 10 FEET (3048 MM). |
| EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER |
| PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL |
| WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE |
| CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. |
| IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE |
| BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 |
| PERCENT AWAY FROM THE BUILDING. |
| |
| CITY AMENDMENTS SEC. 107.2.5 SITE PLAN. THE |
| CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION |
| FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING |
| TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND |
| EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT |
| LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED |
| FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE |
| AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND |
| DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN |
| ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY |
| LINE SURVEY. IN THE CASE OF DEMOLITION, THE SITE PLAN |
| SHALL SHOW CONSTRUCTION TO BE DEMOLISHED AND THE |
| LOCATION AND SIZE OF EXISTING STRUCTURES AND |
| CONSTRUCTION THAT ARE TO REMAIN ON THE SITE OR PLOT. |
| THE BUILDING OFFICIAL IS AUTHORIZED TO WAIVE OR MODIFY |
| THE REQUIREMENT FOR A SITE PLAN WHEN THE APPLICATION |
| FOR PERMIT IS FOR ALTERATION OR REPAIR OR WHEN |
| OTHERWISE WARRANTED. |
| |
| |
| 6- ROOF PLAN ON SHEET S-1: |
| A) RESPONSE: NOT ADDRESSED. |
| |
| ORIGINAL COMMENT: |
| SPECIFY THE CONNECTORS AT ALL ENDS OF ALL THE FRAMING |
| MEMBERS SPECIFIED ON THE FRONT PORCH AREA. COORDINATE |
| WITH DETAIL 1 ON SHEET A-3. SEC. R301.1 |
| FBC-RESIDENTIAL. |
| |
| B) RESPONSE: NOT ADDRESSED. |
| |
| ORIGINAL COMMENT: |
| PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| FRAMING OF THE OUT-LOOKERS AT THE FRONT GABLE AREA. |
| COORDINATE WITH DETAIL 1 ON SHEET A-3. SEC. R301.1 |
| FBC-RESIDENTIAL. |
| |
| C) RESPONSE: NOT ADDRESSED. |
| |
| ORIGINAL COMMENT: |
| PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| BEAMS AT THE REAR PORCH. THERE IS NOT PRECAST LINTEL |
| SCHEDULE. SEC. R301.1 FBC-RESIDENTIAL. |
| |
| 7- COMPLIED. |
| |
| 8- COMPLIED. |
| |
| 9- SHEET A-2: |
| A) COMPLIED?. |
| |
| B) COMPLIED. |
| |
| C) SEMI-COMPLIED. NOTE: IF THERE IS ANY DISCREPANCY |
| BETWEEN THE REFERENCED MANUAL AND FBC AND PRODUCT |
| APPROVAL SUBMITTED, THEN FBC AND PRODUCT APPROVAL |
| PREVAILS. |
| |
| ORIGINAL COMMENT: |
| CLARIFY WHY REFERENCING "THE ARMA RESIDENTIAL ROOFING |
| MANUAL 2006". THIS STANDARD IS NOT REFERENCED IN THE |
| FLORIDA BUILDING CODE. SEE SEC. R905.2 FBC-RESIDENTIAL |
| AND REVISE AS REQUIRED. REVISE AS REQUIRED ON WALL |
| SECTIONS #5 AND #6. NOTE: REVISE DETAIL #2 ON SHEET A-3 |
| AND DETAIL #1 ON SHEET A-4 AS WELL. |
| |
| D) COMPLIED. |
| |
| 10- SECTION 5 ON SHEET S-3: |
| A) RESPONSE: NOT ADDRESSED. |
| |
| ORIGINAL COMMENT: |
| PROVIDE COMPLETE SPECIFICATIONS FOR THE BASE PLATE |
| FASTENERS. SPECIFY HOW MUCH EMBEDMENT IS REQUIRED. WHAT |
| DOES H.S STANDS FOR?. THERE IS NOT ABBREVIATION LEGEND. |
| NOTE: COORDINATE INFORMATION WITH STEEL COLUMN SCHEDULE |
| ON SHEET S-1, INCLUDING SIZE OF PLATE. REVISE AS |
| REQUIRED TO MATCH. SEC. R301.1 FBC-RESIDENTIAL. |
| |
| |
| B) RESPONSE: NOT ADDRESSED. |
| |
| ORIGINAL COMMENT: |
| WELDING INFORMATION FOR THE STEEL COLUMN AT TOP AND |
| BOTTOM PLATES IS INCOMPLETE. ONLY THE WELDING SYMBOL IS |
| PROVIDED. PROVIDE COMPLETE SPECIFICATIONS. SEC. R301.1 |
| FBC-RESIDENTIAL. |
| |
| 11- REVISE ENERGY CALCULATIONS SUBMITTED: |
| A) COMPLIED. |
| |
| B) COMPLIED. |
| |
| C) COMPLIED. |
| |
| D) COMPLIED. |
| |
| E) COMPLIED. |
| |
| 12- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: (NOTE: ALL |
| PRODUCT APPROVALS WILL BE SUBMITTED LATER AS DEFERRED |
| SUBMITTAL) |
| A) ENTRY DOOR WITH SIDELITES AND TRANSOM AS SHOWN ON |
| PLANS. |
| B) SINGLE HUNG WINDOWS AS SPECIFIED ON PLANS. |
| C) HORIZONTAL ROLLER WINDOWS AS SPECIFIED ON PLANS. |
| D) SLIDING GLASS DOORS AS SHOWN ON PLANS. |
| E) HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE |
| HURRICANE IMPACT GLAZING. AND, PROVIDE COMPLETE |
| INSTALLATION SCHEDULE. SEE CITY SAMPLE. |
| F) ROOF SHINGLES. |
| G) ROOF SHINGLES UNDERLAYMENT AS SPECIFIED ON PLANS. |
| H) RIDGE VENTS AS SPECIFIED ON PLANS. SEE SHEET A-1. |
| I) PRECAST LINTELS AS SPECIFIED ON PLANS. |
| |
| 13- DESIGNER OF RECORD TO REVIEW AND APPROVE ALL |
| PRODUCT APPROVALS (NOT SIGNING AND SEALING). |
| |
| 14- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO |
| LOW. VALUE TO INCLUDE ALL LABOR, MATERIALS, |
| CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN |
| PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY |
| AMENDMENTS. VALUATION WAS UPDATED TO $192,608. THE |
| PERMIT FEE BALANCE IS $3,674.29. |
| NOTE: PROVIDE COPY OF THE CONSTRUCTION CONTRACT/COST |
| BREAKDOWN AS REQUESTED BY ROBERT BROWN (BUILDING |
| OFFICIAL). COORDINATE WITH ARMANDO FANA. DIRECTOR, |
| HOUSING AND COMMUNITY DEVELOPMENT. |
| |
| |
| *****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. |
| ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |
| FOR REFERENCE AND HELP EXPEDITE THE REVIEW PROCESS. |
| |