Plan Review Notes
Plan Review Notes For Permit 17120802
Permit Number 17120802
Review Stop B
Sequence Number 2
Notes
Date Text
2018-04-20 15:24:52 
  
 *****REVIEW IN PROGRESS...... NOT FINAL YET
  
  
 NEW SINGLE FAMILY RESIDENCE (R3), SECOND BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEE ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
 NOTE: THIS MAY BE DONE LATER WHEN THE PLANS ARE
 APPROVED AND STAMPED BY THE CITY.
  
 2- COMPLIED.
  
 3- SHEET A-1. REVISE THE EGRESS WINDOWS NOTE THAT IS
 LOCATED BELOW THE WINDOW SCHEDULE:
 A) COMPLIED.
 B) COMPLIED.
 C) COMPLIED.
  
 4- COMPLIED.
  
 5- RESPONSE: NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH SEC.
 R401.3 FBC-RESIDENTIAL.
 R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN
 SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE
 SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE
 FIRST 10 FEET (3048 MM).
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
 IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE
 BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2
 PERCENT AWAY FROM THE BUILDING.
  
 6- ROOF PLAN ON SHEET S-1:
 A) RESPONSE: NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 SPECIFY THE CONNECTORS AT ALL ENDS OF ALL THE FRAMING
 MEMBERS SPECIFIED ON THE FRONT PORCH AREA. COORDINATE
 WITH DETAIL 1 ON SHEET A-3. SEC. R301.1
 FBC-RESIDENTIAL.
  
 B) RESPONSE: NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 FRAMING OF THE OUT-LOOKERS AT THE FRONT GABLE AREA.
 COORDINATE WITH DETAIL 1 ON SHEET A-3. SEC. R301.1
 FBC-RESIDENTIAL.
  
 C) RESPONSE: NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 BEAMS AT THE REAR PORCH. THERE IS NOT PRECAST LINTEL
 SCHEDULE. SEC. R301.1 FBC-RESIDENTIAL.
  
 7- COMPLIED.
  
 8- COMPLIED.
  
 9- SHEET A-2:
 A) COMPLIED?.
  
 B) COMPLIED.
  
 C) SEMI-COMPLIED. NOTE: IF THERE IS ANY DISCREPANCY
 BETWEEN THE REFERENCED MANUAL AND FBC AND PRODUCT
 APPROVAL SUBMITTED, THEN FBC AND PRODUCT APPROVAL
 PREVAILS.
  
 ORIGINAL COMMENT:
 CLARIFY WHY REFERENCING "THE ARMA RESIDENTIAL ROOFING
 MANUAL 2006". THIS STANDARD IS NOT REFERENCED IN THE
 FLORIDA BUILDING CODE. SEE SEC. R905.2 FBC-RESIDENTIAL
 AND REVISE AS REQUIRED. REVISE AS REQUIRED ON WALL
 SECTIONS #5 AND #6. NOTE: REVISE DETAIL #2 ON SHEET A-3
 AND DETAIL #1 ON SHEET A-4 AS WELL.
  
 D) COMPLIED.
  
 10- SECTION 5 ON SHEET S-3:
 A) RESPONSE: NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 PROVIDE COMPLETE SPECIFICATIONS FOR THE BASE PLATE
 FASTENERS. SPECIFY HOW MUCH EMBEDMENT IS REQUIRED. WHAT
 DOES H.S STANDS FOR?. THERE IS NOT ABBREVIATION LEGEND.
 NOTE: COORDINATE INFORMATION WITH STEEL COLUMN SCHEDULE
 ON SHEET S-1, INCLUDING SIZE OF PLATE. REVISE AS
 REQUIRED TO MATCH. SEC. R301.1 FBC-RESIDENTIAL.
  
  
 B) RESPONSE: NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 WELDING INFORMATION FOR THE STEEL COLUMN AT TOP AND
 BOTTOM PLATES IS INCOMPLETE. ONLY THE WELDING SYMBOL IS
 PROVIDED. PROVIDE COMPLETE SPECIFICATIONS. SEC. R301.1
 FBC-RESIDENTIAL.
  
 11- REVISE ENERGY CALCULATIONS SUBMITTED:
 A) COMPLIED.
  
 B) COMPLIED.
  
 C) COMPLIED.
  
 D) COMPLIED.
  
 E) COMPLIED.
  
  
  
  
  
 12- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) ENTRY DOOR WITH SIDELITES AND TRANSOM AS SHOWN ON
 PLANS.
  
 B) SINGLE HUNG WINDOWS AS SPECIFIED ON PLANS.
  
 C) HORIZONTAL ROLLER WINDOWS AS SPECIFIED ON PLANS.
  
 D) SLIDING GLASS DOORS AS SHOWN ON PLANS.
  
 E) HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 HURRICANE IMPACT GLAZING. AND, PROVIDE COMPLETE
 INSTALLATION SCHEDULE. SEE CITY SAMPLE.
  
 F) ROOF SHINGLES.
  
 G) ROOF SHINGLES UNDERLAYMENT AS SPECIFIED ON PLANS.
 (COORDINATE WITH ITEM #9(B) ABOVE.
  
 H) RIDGE VENTS AS SPECIFIED ON PLANS. SEE SHEET A-1.
  
 I) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 13- DESIGNER OF RECORD TO REVIEW AND APPROVE ALL
 PRODUCT APPROVALS (NOT SIGNING AND SEALING) AS REQUIRED
 BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 14- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUE TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. VALUATION WAS UPDATED TO $192,608. THE
 PERMIT FEE BALANCE IS $3,674.29.
  
 *****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE AND HELP EXPEDITE THE REVIEW PROCESS.
  