Date |
Text |
2021-02-22 14:08:33 | NEW SINGLE FAMILY RESIDENCE R3) SECOND BUILDING REVIEW |
| COMMENTS |
| CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| PERMIT#17120309 |
| |
| 1- OK |
| |
| 2- OK |
| |
| ORIGINAL COMMENT: |
| 3- IT LOOKS LIKE SECOND FLOOR SINGLE HUNG EGRESS |
| WINDOWS #2 HAVE THE WINDOW SILL LOCATED LESS THAN 24 |
| INCHES ABOVE THE FINISH FLOOR. NEED TO COMPLY WITH THE |
| WINDOW FALL PROTECTION SEC. R312.2 FBC-RESIDENTIAL. |
| PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING |
| COMPLIANCE. |
| |
| RESPONSE: |
| SIZE OF SINGLE HUNG EGRESS WINDOW #2 WAS REVISED. NEW |
| SIZE DOESN'T SEEM TO COMPLY WITH THE EGRESS |
| REQUIREMENTS OF SEC. R310.2.1 FBC-RESIDENTIAL. 4'-11" |
| HEIGHT SINGLE HUNG WINDOW DOESN'T SEEM PROVIDE THE MIN. |
| 24" CLEAR HEIGHT OPENING. REVISE SIZE OF WINDOW OR |
| PROVIDE MANUFACTURER'S CUT SHEETS SHOWING THAT |
| SPECIFIED WINDOW SIZE WILL MEET ALL THE EGRESS |
| REQUIREMENTS. CLEAR HEIGHT, CLEAR WIDTH AND TOTAL CLEAR |
| OPENING (5.7 S.F. MIN.). |
| |
| 4- OK |
| |
| 5- OK |
| |
| 6-DEFERRED SUBMITTALS: |
| WINDOWS, DOORS, SHUTTERS IF DOORS WITH GLAZING AND |
| WINDOWS DON'T HAVE IMPACT GLASS, ROOFING AND ROOF |
| VENTS, ALUMINUM SOFFITS, RAILINGS AND GUARDRAILS. |
| DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE |
| SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN |
| RESPONSIBLE CHARGE FOR REVIEW PRIOR TO SUBMITTAL TO |
| THIS OFFICE. SEC. 107.3.4.1 CITY AMENDMENTS. |
| |
| 7- OK |
| |
| PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| QUESTIONS REGARDING THESE COMMENTS, |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |
| [email protected] |
| |