2018-01-02 13:50:18NEW SINGLE FAMILY RESIDENCE (R3), BUILDING REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEE ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
  
 2- DRAWINGS NEED TO HAVE THE CORRECT ADDRESS. THE HOUSE
 IS LOCATED ON WINDSOR AVE NOT WINDSOR CT. ALSO, THE
 CORRECT ZIP CODE IS 33407 NOT 33401. THE ASSIGNED
 ADDRESS FOR THIS NEW HOUSE IS 3719 WINDSOR AVE, WEST
 PALM BEACH FL 33407. REVISE INFORMATION ON ALL PLANS AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 3- FLOOR PLAN ON SHEET 1.
 A) SPECIFY THE SIZE OF THE ENTRY DOOR TO VERIFY
 COMPLIANCE WITH SEC. R311.2 FBC-RESIDENTIAL, 5TH
 EDITION (2014).
  
 B) SPECIFY SELF CLOSING DEVICE FOR DOOR LEADING FROM
 THE GARAGE TO THE MAIN HOUSE AS REQUIRED BY SEC.
 R302.5.1 FBC RESIDENTIAL.
  
 4- REVISE THE GRAVITY LOADS SPECIFIED ON SHEET T-1.
 NEED TO REVISE THE ATTIC LIVE LOAD TO COMPLY WITH TABLE
 R301.5 FBC-RESIDENTIAL.
  
 5- REVISE STRUCTURAL NOTE #3 ON SHEET T-1. ACCORDING TO
 ASTM C 1063 THE HIGH RIB METAL LATH NEED TO BE NAILED
 WITH NAILS OR STAPLES THAT PROVIDE MIN. 1-3/4"
 PENETRATION INTO THE ROOF TRUSS. THEREFORE THE 1-1/2"
 NAILS DON'T COMPLY. REVISE AS REQUIRED.
  
 6- JOBSITE LOCATION MAP SHOWN ON SHEET D-1 DOESN'T
 CORRESPOND TO PROPOSED LOCATION. REVISE AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 7- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. VALUATION WAS UPDATED TO $215,855. THE
 PERMIT FEE BALANCE IS $4137.66.
  
 8- ENERGY CALCULATIONS SUBMITTED:
 A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM
 INCLUDING THE HOUSE ADDRESS (3719 WINDSOR AVE WPB. FL
 33407), OWNER'S NAME AND BUILDER'S NAME. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 B) CONCRETE BLOCK WALL INSULATION SPECIFIED ON ITEM #9
 DOESN'T MATCH PLANS. REVISE AS REQUIRED TO MATCH. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 C) CEILING INSULATION SPECIFIED ON ITEM #10 DOESN'T
 MATCH PLANS. REVISE AS REQUIRED TO MATCH. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 D) PROVIDE THE NAME OF THE PERSON RESPONSIBLE FOR THE
 DESIGN AS REQUIRED BY SEC. R405.4.2 FBC-ENERGY
 CONSERVATION.
  
 E) DOORS INFORMATION ON PAGE 3 OF 4 SPECIFIES AN
 INSULATED DOOR ON THE SOUTH. PLANS DON'T SHOW ANY
 INSULATED DOOR ON THE SOUTH SIDE. CLARIFY WHERE IS THIS
 DOOR LOCATED AT. REVISE AS REQUIRED TO MATCH PLANS.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 F) WINDOWS INFORMATION SHOWN ON PAGE 3 OF 4 DOESN'T
 MATCH PLANS. REVISE THE ORIENTATION, AREA AND OVERHANG
 DEPTH AND SEPARATION TO MATCH PLANS. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 G) GARAGE FLOOR AREA AND CEILING AREA SHOWN ON PAGE 3
 OF 4 DOESN'T MATCH PLANS. REVISE AS REQUIRED TO MATCH.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 H) BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-ENERGY
 CONSERVATION.
  
 NOTE:
 LABEL REQUIRED FOR DOORS AND WINDOWS SHOWING THE
 U-FACTOR AND SHGC FACTOR SPECIFIED IN THE ENERGY
 CALCULATIONS IS REQUIRED WHEN THE CALCULATIONS DON'T
 USE THE PROGRAM'S DEFAULT FACTOR.
  
 9- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) ENTRY DOOR WITH SIDELITE AS SHOWN ON PLANS.
  
 B) OVERHEAD GARAGE DOOR AS SHOWN ON PLANS.
  
 C) SINGLE HUNG WINDOWS AS SHOWN ON PLANS.
  
 D) SLIDING GLASS DOORS AS SHOWN ON PLANS.
  
 E) HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT GLAZING. AND PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
  
 F) ROOF SHINGLES AS SHOWN ON PLANS.
  
 G) GABLE VENT AS SHOWN ON THE FRONT ELEVATION.
  
 H) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 10- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 11- PROVIDE SITE PLANS OR SURVEY SHOWING THE PROPOSED
 HOUSE AND THE PROPERTY LINES AS REQUIRED BY SEC.
 107.3.5.3(1) CITY AMENDMENTS.
  
 12- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 COLONIAL SHUTTERS SHOWN ON THE FRONT ELEVATION. SPECIFY
 SHUTTERS MATERIAL AND FASTENING SPECIFICATIONS. SEC.
 R301.1 FBC-RESIDENTIAL.
  
 13- GABLE END DETAIL ON SHEET T-1:
 A) SPECIFY STUCCO THICKNESS (7/8") AS REQUIRED BY TABLE
 R702.1(1) FBC-RESIDENTIAL.
  
 B) SPECIFY TWO LAYERS OF WATER-RESISTIVE BARRIERS AS
 REQUIRED BY SEC. R703.6.3 FBC-RESIDENTIAL.
  
 14- PROVIDE COMPLETE GARAGE DOOR STRUCTURAL BUCK
 DETAIL. SPECIFY BUCK SIZE AND FASTENER TYPE AND
 SPACING. SEC. R301.1 FBC-RESIDENTIAL.
  
 ****PLEASE PROVIDE RESPONSE LETTEER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]