2018-04-06 12:10:401. NOT SATISFIED. SHEET A1-1-1 IS DIFFERENT THAN SHEET
 A1-1-2 , PLEASE ADJUST ALL DRAWINGS TO REFLECT THE SAME
 INFORMATION. SHEET A1-1-1 INDICATES THE STAIR ENDING
 NORTH OF THE PROJECTION OF THE PLANTER (DRAWING NOT
 DIMENSION THEREFORE CONFIRMATION NOT POSSIBLE BY
 STAFF), IT SEEMS AN ACCEPTABLE CONDITION, BUT DIMENSION
 DRAWING NEEDED TO CONFIRM. - 1/17/18- A MINIMUM 8'
 CLEAR SIDEWALK SHALL BE PROVIDED AROUND THE PROJECT.
 THE MAIN STAIR AT THE CORNER OF FLAGLER DRIVE AND
 BANYAN BLVD IS ENCROACHING TOO MUCH INTO THE CLEAR
 SIDEWALK PATH. ONE FOOT OF THE TREE GRATE CAN BE
 COUNTED TOWARDS THE CLEAR PATH IF NEEDED.
 2. NOT SATISFIED - 1/18/19. ARTIFICAL GRASS IS NOT
 ALLOWED IN ANY LOCATION VISIBLE FROM THE PUBLIC RIGHT
 OF WAY.
 3. NOT SATISFIED. IN ADDITION TO THE ELEMENTS MENTIONED
 IN PREVIOUS REVIEW, THE AMOUNT OF WINDOWS ALONG BANYAN
 BLVD HAS ALSO BEEN REDUCED. PLEASE SUBMTI INFORMATION
 TO CONFIRM COMPLIANCE WITH THE MINIMUM 50% TRANSPARENCY
 REQUIRED ALONG BANYAN BOULEVARD. -1/17/18 .ORIGINAL
 APPROVAL INCLUDED AN EYE BROW ELEMENT ALONG BANYAN
 BOULEVARD AND A METAL MESH ELEMENT AT THE CORNER OF
 NARCISSUS AVE AND BANYAN BLVD TO ENHANCE THE BLANK
 FACADE. THOSE ELEMENTS SHALL NOT BE REMOVED AS THEY
 WERE APPROVED AS PART OF THE ARCHITECTURAL DESIGN
 PRESENTED TO THE DAC.
 4. SP1-01 STILL SHOWS DOOR, PLEASE ADJUST ALL DRAWING.-
 1/17/18 -ORIGINAL APPROVAL DID NOT INCLUDE A MECHANICAL
 DOOR ALONG NARCISSUS AVENUE. IF THE DOOR SHALL REMAIN
 AT THAT LOCATION ITS APPEARANCE SHALL BE IMPROVED.
 ORIGINAL APPROVAL DEPICTS A WINDOW.
 5. ACCORDING TO CURRENT SIGN REGULATION, ONLY SIGNAGE
 ALLOWED IS FOR TENANT ON FIRST FLOOR.-1/17/18 -SIGNAGE
 IS NOT INCLUDED UNDER THIS PERMIT. SECODN FLOOR TENANT
 IS NOT ALLOWED TO HAVE SIGN ON BUILDING FACADE. A
 PEDESTRIAN BLADE SIGN WILL BE PERMITTED.
 6. SATISFIED - 1/17/18-ROOF TOP TERRACE DOES NOT
 INCLUDE ANY VEGETATION OR ANY ROOF SCREENING FOR
 MECHANICAL EQUIPMENT. HOTEL ROOMS WILL HAVE A DIRECT
 VIEW OF MECHANICAL EQUIPMENT.
 7. APPLICANT'S RESPONSE ACKNOWLEDGED. STAFF WILL
 DISCUSS WITH ENG. DEPARTMENT FOR FINAL
 DETERMINATION.-1/17/18 -PLEASE PROVIDE A PEDESTRIAN
 CROSSING AT NARCISSUS AVE AND 2ND STREET TO CONNECT
 WITH THE PARK ON THE NORTH SIDE.
 8. OK- 1/17/18- CAN THE PROPOSED SWITCH CABINET ALONG
 NARCISSUS BE RELOCATED AWAY FROM THE PEDESTRIAN PATH OF
 TRAVEL?
 9. DETAIL OF SPECIFIC LIGHT FIXTURE ARE NEEDED.
 -1/19/18.PLEASE PROVIDE SPECS FOR LIGHT FIXTURES AND
 POLES ON ROW. FLAGLER POLES AND FIXTURES SHALL MATCH
 THE WATERFRONT DESIGN, AND OTHER STREETS SHALL FOLLOW
 THE DOWNTOWN STANDARD. IF ANY COBRA HEADS EXISTS, THEY
 SHOUDL BE REMOVED AND REPLACED BY DECORATIVE.
 10.OK- 1/17/18- STAFF RECOMMENDS NARCISSUS AVE TO BE
 DESIGNED AS A CURBLESS ROAD TO FACILITATE THE
 RELATIONSHIP BETWEEN THE HOTEL AND THE PARK.
 11. OK - 1/17/18. ADA RAMPS AT CORNRES SHALL BE
 DESIGNED TO REDUCED PEDESTRIAN DISTANCE AT CROSSING.
 STAFF SUGGEST DOING TWO RAMPS INSTEAD OF ONE.
 12. OK- 1/17/18. PLEASE COORDINATE WITH THE CITY FOR
 THE REDESIGN OF THE FLAGLER DRIVE AND BANYAN BOULEVARD
 INTERSECTION. CHANGES MAY AFFECT PROJECT STARS.
 13. CITY RECORDS DO NOT SHOW A SEPARATE LANDSCAPE
 PERMIT FOR ANY OF THE 3 PROJECTS ASSOCIATED WITH THE
 OLD CITY HALL SITE. PLEASE SUBMIT A SEPARATE LANDSCAPE
 PERMIT. 1/19/18. A SEPARATE LANDSCAPE PERMIT SHALL BE
 SUBMITTED FOR THE PROJECT. AN ENGINEERING PERMIT WILL
 BE REQUIRED FOR THE LANDSCAPE ON THE ROW.
 14. OK - 1/17/18.FURTHER DISCUSSION IS NECESSARY FOR
 THE DESIGN OF THE PUBLIC PARK.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.