Plan Review Notes For Permit 17110425 |
Permit Number |
17110425 |
|
Review Stop |
Z |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2017-11-22 08:08:26 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) SHOW SETBACK DIMENSION FROM THE LOCATION OF THE | | PROPOSED A/C PAD TO THE PROPERTY LINE. THE PAD CANNOT | | PROJECT MORE THAN 4 FT. INTO THE REQUIRED SIDE SETBACK. | | [ZLDR S.94-305] | | | | 2.) NO DIMENSIONS PROVIDED FOR THE PROPOSED DRIVEWAY. | | DRIVEWAY CANNOT EXCEED 20 FT. IN WIDTH [ZLDR S.94-312] | | | | 3.) 1,000 SQ. FT. OR 75 PERCENT OF THE FRONT YARD | | (FIRST 25 FT. FROM THE FRONT PROPERTY LINE ON 54TH | | STREET) SHALL BE LANDSCAPED WITH LIVING PLANT MATERIAL. | | PLEASE PROVIDE FRONT YARD PERVIOUS AND IMPERVIOUS | | SURFACE CALCULATIONS TO DEMONSTRATE COMPLIANCE. [ZLDR | | S.94-482] | | | | | | NOTES: | | | | * A SEPARATE LANDSCAPE PERMIT WILL BE REQUIRED PRIOR TO | | CERTIFICATE OF OCCUPANCY. | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * ZONE: SF7 | | |
|