Plan Review Notes
Plan Review Notes For Permit 17101220
Permit Number 17101220
Review Stop B
Sequence Number 1
Notes
Date Text
2017-10-31 07:43:582014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17101220
 ADD: 349 MADDOCK ST.
 CONT: MOLSBEE ROOFING
 TEL: 561-318-8624
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. OCT. 31/ 2017
 ACTION: BUILDING PROVISO
  
 ROOFING ASPHALT SHINGLES 2014< 4/12 PITCH.
 R905.2.7 UNDERLAYMENT APPLICATION.
 UNDERLAYMENT SHALL BE INSTALLED USING
 ONE OF THE FOLLOWING METHODS:
  
 1) FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS
 HORIZONTAL (17-PERCENT SLOPE), AND LESS THAN FOUR UNITS
 VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE).
 UNDERLAYMENT SHALL COMPLY WITH ASTM D 226, TYPE I
 OR TYPE II OR ASTM D 4869, TYPE II OR TYPE IV OR ASTM D
 6757 AND SHALL BE TWO LAYERS APPLIED IN THE FOLLOWING
 MANNER. APPLY A 19-INCH (483 MM) STRIP OF UNDERLAYMENT
 FELT PARALLEL TO AND STARTING AT THE EAVES, FASTENED
 SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE,
 APPLY
 36-INCH-WIDE (914 MM) SHEETS OF UNDERLAYMENT,
 OVERLAPPING SUCCESSIVE SHEETS 19 INCHES.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  