 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) PROVIDE A FLOOR PLAN OF THE STRUCTURE WITH THE ROOM
 TYPES LABELED. SPECIFY THE LOCATIONS OF THE WINDOW AND
 DOOR THAT ARE TO BE REPLACED. SPECIFY THE SIZES OF THE
 WINDOW AND DOOR THAT ARE TO REPLACED. INDICATE THE
 SWING OF THE DOOR (IN-SWING OR OUT-SWING). FBC 107.2.1
  
 2) THE PRODUCT APPROVAL FOR THE WINDOW STATES THAT THE
 WINDOW IS NOT RATED FOR LARGE MISSILE IMPACT. INDICATE
 ON THE PLANS IF THERE ARE EXISTING HURRICANE PANELS OR
 PROVIDE CALCULATIONS TO SHOW THAT THE AGGREGATE AREA OF
 THE GLAZING IN THE REPLACED COMPONENTS DOES NOT EXCEED
 25 PERCENT OF THE AGGREGATE AREA OF THE GLAZED OPENINGS
 IN THE DWELLING.
 706.4 REPLACEMENT OF WINDOWS AND DOORS.
 THE REPLACEMENT OF GARAGE DOORS, EXTERIOR DOORS,
 SKYLIGHT, OPERATIVE AND INOPERATIVE WINDOWS SHALL BE
 DESIGNED AND CONSTRUCTED TO COMPLY WITH CHAPTER 16 OF
 THE FLORIDA BUILDING CODE, BUILDING.
 EXCEPTIONS: 1. OPENING PROTECTION EXCEPTION. FOR ONE-
 AND TWO-FAMILY DWELLINGS CONSTRUCTED UNDER CODES OTHER
 THAN THE FLORIDA BUILDING CODE AND LOCATED IN WINDBORNE
 DEBRIS REGIONS, THE REPLACEMENT OF GARAGE DOORS AND
 EXTERIOR DOORS WITH GLAZING, SLIDING GLASS DOORS, GLASS
 PATIO DOORS, SKYLIGHTS, AND OPERABLE AND INOPERABLE
 WINDOWS WITHIN ANY 12-MONTH PERIOD SHALL NOT BE
 REQUIRED TO HAVE OPENING PROTECTION BUT SHALL BE
 DESIGNED FOR WIND PRESSURES FOR ENCLOSED BUILDINGS,
 PROVIDED THE AGGREGATE AREA OF THE GLAZING IN THE
 REPLACED COMPONENTS DOES NOT EXCEED 25 PERCENT OF THE
 AGGREGATE AREA OF THE GLAZED OPENINGS IN THE DWELLING
 OR DWELLING UNIT.
  
 3) IF THIS WINDOW IS IN A SLEEPING ROOM, SHOW THAT IT
 COMPLIES WITH FBC EXISTING BUILDING SECTION 704.
 SECTION 704
 MEANS OF EGRESS
 704.1 GENERAL.
 MEANS OF EGRESS FOR BUILDINGS UNDERGOING ALTERATION
 SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 701.1 AND
 THE SCOPING PROVISIONS OF CHAPTER 1 WHERE APPLICABLE.
 EXCEPTION: DOOR AND WINDOW DIMENSIONS. IN RESIDENTIAL
 DWELLINGS AND DWELLING UNITS, A MAXIMUM OF 5-PERCENT
 REDUCTION IN THE CLEAR OPENING DIMENSIONS OF
 REPLACEMENT DOORS AND WINDOWS SHALL BE ALLOWED.
  
  