Plan Review Notes For Permit 17100471 |
Permit Number |
17100471 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2017-11-17 14:30:10 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. PLEASE REVISE SHT. A0-41 TO SHOW BATHROOM #4 AS THE | | SPEC B BATH PER FHA DESIGN MANUAL | | | | 2. WHEN THE DOOR SWINGS INTO THE USABLE BATHROOM IT IS | | REQUIRED TO HAVE A 30" X 48" CLEAR FLOOR SPACE OUTSIDE | | THE ARC OF THE DOOR SWING, THE LAYOUT FOR BATHROOM #4 | | IN UNIT 10D SHOWS THIS CLEAR FLOOR SPACE BEHIND THE | | DOOR WHEN IT IS OPEN WHICH DOES NOT ALLOW A PERSON IN A | | WHEELCHAIR TO ACCESS THIS SPACE IN ORDER TO CLOSE THE | | DOOR I SUGGEST THE DOOR TO SWING OUT INTO THE BEDROOM | | IN ORDER TO COMPLY. PER FHA DESIGN MANUAL PG. 7.39 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|