Plan Review Notes For Permit 17100242 |
Permit Number |
17100242 |
|
Review Stop |
B |
Sequence Number |
3 |
|
Notes |
Date |
Text |
2017-10-31 06:52:09 | STAMPED DELEGATED ENGINEERING | | RETAINED 1 SET OF SHOP DRAWINGS & ENGINEERING/CALCS | | | | ****PROVISO**** | | ISSUED AT APPLICANT'S RISK | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | PLEASE NOTE THAT THE BOTTOM RISER IS SHOWN GRAPHICALLY | | AS SMALLER THAN THE OTHER RISERS (FBC B 1009.7.4), AND | | ONE DIMENSION APPEARS TO SHOW A 7 5/8" RISER DIMENSION | | (SHOULD BE 7" MAX, FBC B 1009.7.2). | | | | A COMPREHENSIVE PLAN REVIEW IS NOT PERFORMED ON | | DELEGATED ENGINEERING AS THE ENGINEERING IS TO COMPLY | | WITH THE FLORIDA BUILDING CODE AND THE | | APPROVED/REVIEWED PLAN. DEVIATION FROM THE PLANS AND/OR | | FBC IS TO BE SUBMITTED AS A REVISION FROM THE DESIGNER | | OF RECORD. | | | | INSTALLATION TO BE IN ACCORDANCE WITH THE REVIEWED | | PLANS (PERMIT DOCUMENTS) PERMITTED UNDER MASTER PERMIT | | #15020937 AND FBC 2014. ANY DEVIATION FROM THE ISSUED | | MASTER PERMIT OR FBC 2014 IS REQUIRED TO BE SUBMITTED | | AS A REVISION, PREPARED BY DESIGNER OF RECORD. | | | | |
|