2017-10-16 07:44:32 | PLAN |
| REVIEW COMMENTS |
| |
| 1ST REVIEW: FBC FIFTH EDITION (2014) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| PROVIDE THE FOLLOWING INFORMATION FOR FLOORING |
| SUBMITTALS: |
| |
| 1. FLOOR PLAN WITH DIMENSIONS AND LOCATION OF WORK. |
| > DESIGNER TO PRINT NAME AND SIGN PLAN PER FBC 107. |
| 2. TOTAL SQUARE FOOTAGE OF NEW FLOORING. |
| 3. TYPE OF PROPOSED HARD FLOORING (TILE, LAMINATE, |
| WOOD, MARBLE, ETC.). |
| 4. DESCRIPTION OF EXISTING SITE CONDITIONS: |
| (A) THICKNESS OF SLAB (B) FLOOR/CEILING ASSEMBLY BELOW |
| (EXPOSED CONCRETE, SUSPENDED GYPSUM OR ACOUSTICAL ). |
| 5. PROPOSED UNDERLAYMENT. |
| 6. TEST REPORTS FOR THE PROPOSED UNDERLAYMENT BASED ON |
| THE EXISTING SITE CONDITIONS. |
| 7. TEST REPORTS MAY BE BASED ON THE FOLLOWING ASTM'S: |
| E-84, E-90 & E-492. |
| 8. ALL DOCUMENTS SHALL BE SUBMITTED IN DUPLICATE. |
| |
| FBC 603.1 FLAME SPREAD - ASTM E 84-09 |
| |
| FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04 |
| WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| E 90. |
| |
| FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09 |
| FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| |
| SUBMIT TWO COPIES OF THE TEST REPORTS FOR THE SOUND |
| INSULATION INCLUDING FLAME SPREAD AND SMOKE DEVELOPED |
| FOR THE APPLICABLE CONSTRUCTION CONDITIONS. |
| |