Plan Review Notes For Permit 17090752 |
Permit Number |
17090752 |
|
Review Stop |
R |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2017-12-12 17:00:22 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) BALCONIES WATERPROOFING UNDERLAYMENT. PROVIDE | | FLORIDA PRODUCT APPROVAL OR MIAMI DADE NOA FOR THE | | MASTERSEAL 550 WATERPROOFING SUBMITTED THIS TIME. NEED | | PRODUCT APPROVAL FOR CONCRETE DECK THAT IS DESIGNED TO | | RECEIVE FINISH FLOOR AS SPECIFIED BY THE ARCHITECT OF | | RECORD. CLEARLY MARK SPECIFIC ASSEMBLY TO BE INSTALLED | | AND PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF | | THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES | | FOR ALL DECK ZONES. IF THERE IS NOT PRODUCT APPROVAL, | | MANUFACTURER MAY SUBMIT COMPLETE ORIGINAL ENGINEERING | | PACKAGE FOR BUILDING OFFICIAL APPROVAL. NOTE: THERE ARE | | SEVERAL PRODUCTS THAT ALREADY HAVE A PRODUCT APPROVAL. | | FOR EXAMPLE LOOK AT SEALOFLEX PRODUCTS. | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE ALL PRODUCT | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | AMENDMENTS. NOTE: PLEASE PLACE THE REVIEW STAMP ON THE | | FRONT OF THE PRODUCT APPROVAL NOT ON THE BACK. THIS IS | | REQUIRED FOR PROPER RECORD RETENTION PURPOSES. WHEN THE | | STAMPS ARE PLACED ON THE BACK OF THE PRODUCT APPROVAL, | | THEY DON'T GET SCANNED. SEC. 107.2.1.4 CITY AMENDMENTS. | | | | | | APPROVED: | | 1- METAL ROOF UNDERLAYMENT NOA16-1116.09. | | 2- METAL ROOF SYSTEM NOA 14-0107.04 |
|