Plan Review Notes For Permit 17090693 |
Permit Number |
17090693 |
|
Review Stop |
NFIP |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2017-12-05 11:49:12 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROPOSED HOUSE IS LOCATED IN FLOOD ZONE A5 WITH A | | BASE FLOOD ELEVATION (BFE) OF 7 FEET 0 INCHES. | | 2. PROVIDE ELEVATION CERTIFICATE AS FOLLOWS: | | | | THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS | | A7 WITH A BASE FLOOD ELEVATION (BFE) OF 7FT. THE CITY | | OF WEST PALM BEACH (THROUGH ORDINANCE) REQUIRES AN | | ADDITIONAL 12 INCHES OF FREEBOARD REQUIRING THE DESIGN | | FLOOD ELEVATION (DFE) TO BE 8. 0 FEET. PLEASE NOTE THIS | | INFORMATION ON YOUR PLANS. | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | REQUIRED AT TIME OF PERMIT APPLICATION. | | NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS | | SITE ARE REQUIRED TO BE AT OR ABOVE 8.0 FEET NGVD. | | | | AN UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | RECOMMENDED. | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | | | | |
|