2017-09-27 08:06:471ST REVIEW FBC-2014 BUILDING
 PERMIT #17090629
 9/27/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE W-30 SYSTEM SELECTED HAS A MAXIMUM DESIGN
 PRESSURE OF -60 PSF WHICH IS INADEQUATE FOR ZONES 2 & 3
 ON A ROOF WITH A 10' MEAN HEIGHT IN EXPOSURE C. PLEASE
 SEE LIMITATION 5.7 ON PAGE 4 AND PROVIDE AN ATTACHMENT
 DENSITY DESIGNED BY A FL. LICENSED ENGINEER TO RESIST
 THE ELEVATED PRESSURE CRITERIA.
  