Plan Review Notes
Plan Review Notes For Permit 17090467
Permit Number 17090467
Review Stop B
Sequence Number 1
Notes
Date Text
2017-09-26 14:30:41RESIDENTIAL (R3) REVISION BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
  
 1- REVISE ENERGY CALCULATIONS:
 A) CALCULATIONS NEED TO BE DONE ON THE CORRECT
 ORIENTATION OF THE BUILDING. SEE SURVEY AND PLANS AND
 REVISE WALLS AND WINDOWS INFORMATION AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
 NOTE: CHECK OVERHANG DEPTH AND SEPARATION. MET
 CONTRACTOR ON 10/10/17.
  
 B) WALL TYPES ARE INCORRECT. THERE ARE NO INTERIOR
 STEEL PARTITIONS SEPARATING A/C SPACE FROM NON A/C
 SPACE. PLANS SPECIFY WOOD FRAMED WALLS. SEE PLANS AND
 REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 C) REVISE THE DOORS INFORMATION SHOWN ON PAGE 3 OF 5.
 WHERE ARE THE 16'-0" X 8'-0" INSULATED DOORS?. SEE
 PLANS AND PRODUCT APPROVALS SUBMITTED. NOTE: DOORS WITH
 GLAZING NEED TO BE CONSIDERED IN THE WINDOWS AREA AS
 REQUIRED BY SEC. R405.5.3.3 FBC-ENERGY CONSERVATION.
 REVISE AS REQUIRED.
 RESPONSE: REPEAT COMMENT.
  
  
 2- A/C EQUIPMENT SIZING CALCULATIONS SUBMITTED: PROVIDE
 COMPLETE EQUIPMENT SIZING CALCULATIONS "BASED ON
 BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION OF THE
 BUILDING" AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
 NOTE: IT LOOKS LIKE THE EQUIPMENT SIZING CALCULATIONS
 WERE DONE BY THE SAME PERSON WHO DID THE ENERGY
 CALCULATIONS. THE ENERGY CALCULATIONS NEED TO BE
 REVISED. SEE COMMENTS ON ITEM #1 ABOVE AND REVISE A/C
 EQUIPMENT SIZING CALCULATIONS AS REQUIRED.
  
 3- TRUSS PACKAGE SUBMITTED:
 A) REVISE DESIGN LOADS TO MATCH DESIGN CRITERIA
 SPECIFIED BY THE ENGINEER OF RECORD ON SHEET 2.1. NOTE:
 KEEP IN MIND THAT FINISH ROOF IS CONCRETE TILE.
 SEC. R301.1 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 B) TRUSS LAYOUT AND ALL INDIVIDUAL TRUSS DRAWINGS NEED
 TO BE SIGNED AND SEALED AND HAVE THE TRUSS ENGINEER
 INFORMATION IN ALL DRAWINGS AS REQUIRED BY FAC
 61G15-31.003.
 NOTE: TRUSS LAYOUT WAS NOT SUBMITTED AT THIS TIME. NEED
 TO SUBMIT PROPERLY SIGNED AND SEALED TRUSS LAYOUT.
  
 C) REVISED TRUSS PACKAGE TO BE APPROVED IN WRITING BY
 THE ENGINEER OF RECORD PRIOR TO SUBMITTAL TO THIS
 OFFICE. SEC. 107.3.4.2 CITY AMENDMENTS.
  
 NOTE:
 THE REVISION FEE OF $207.00 WAS NOT PAID. NEED TO PAY
 FEE NOW BEFORE ANY ADDITIONAL REVIEW IS PERFORMED.
 ADDITIONAL FEES WILL BE CHARGED ON EVERY RE-SUBMITTALS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]