Date |
Text |
2017-09-07 11:19:26 | BUILDING PLAN REVIEW |
| 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER, PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| |
| 1ST REVIEW |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. DESIGN PROFESSIONALS SIGNATURE AND SEAL MUST BE |
| ORIGINAL. |
| 2. WALL WILL BE USED AS A POOL BARRIER. BARRIER MUST |
| COMPLY WITH R4501.17. |
| 3. GATES MUST COMPLY WITH R4501.17.1.8. |
| 4. WALL FOOTING CANNOT ENCROACH ONTO ADJACENT PROPERTY. |
| |
| (1) ONLY THE FOLLOWING SEALS ARE AUTHORIZED TO BE USED |
| PURSUANT TO FLORIDA STATUTES ? 471.025; |
| (A) WET SEALS: A WET SEAL IS ANY SEAL PHYSICALLY |
| APPLIED TO A PRINTED DOCUMENT CAPABLE OF LEAVING A |
| PERMANENT INK REPRESENTATION OR OTHER FORM OF OPAQUE |
| PERMANENT IMPRESSION ON THE PRINTED DOCUMENT THAT |
| COMPLIES WITH SUBSECTION 61G15-23.002(2), F.A.C.; |
| (B) EMBOSSING SEALS: AN EMBOSSING SEAL IS ANY SEAL |
| PHYSICALLY APPLIED TO A PRINTED DOCUMENT CAPABLE OF |
| LEAVING A PERMANENT CRIMPED REPRESENTATION OR OTHER |
| FORM OF PERMANENT RAISED IMPRESSION ON THE PRINTED |
| DOCUMENT THAT COMPLIES WITH SUBSECTION 61G15-23.002(2), |
| F.A.C.; OR |
| (C) DIGITALLY CREATED SEALS: A DIGITALLY CREATED SEAL |
| IS ANY SEAL CREATED AS PART OF THE DOCUMENT AND NOT |
| PHYSICALLY APPLIED THAT IS AN OPAQUE PERMANENT |
| REPRESENTATION THAT COMPLIES WITH SUBSECTION |
| 61G15-23.002(2), F.A.C. |
| |
| R4502.17.1 OUTDOOR SWIMMING POOLS. |
| OUTDOOR SWIMMING POOLS SHALL BE PROVIDED WITH A BARRIER |
| COMPLYING WITH SECTIONS R4501.17.1.1 THROUGH |
| R4501.17.1.14. |
| |
| R4501.17.1.8 |
| ACCESS GATES, WHEN PROVIDED, SHALL BE SELF-CLOSING AND |
| SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS |
| R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE EQUIPPED |
| WITH A SELF-LATCHING LOCKING DEVICE LOCATED ON THE POOL |
| SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS LOCATED |
| NO LESS THAN 54 INCHES (1372 MM) FROM THE BOTTOM OF THE |
| GATE, THE DEVICE RELEASE MECHANISM MAY BE LOCATED ON |
| EITHER SIDE OF THE GATE AND SO PLACED THAT IT CANNOT BE |
| REACHED BY A YOUNG CHILD OVER THE TOP OR THROUGH ANY |
| OPENING OR GAP FROM THE OUTSIDE. GATES THAT PROVIDE |
| ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM |
| THE POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING |
| GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457 |
| MM) OF THE RELEASE MECHANISM. |
| |
| |
| |