2020-12-15 11:23:37THIS STRUCTURE IS LOCATED IN A SPECIAL FLOOD HAZARD
 AREA (SFHA). THE BASE FLOOD ELEVATION (BFE) IS 7' NGVD
 '29. THE PERMIT APPLICATION DATE IS AUGUST 29, 2017.
 THE CITY OF WEST PALM BEACH FLOOD ORDINANCE THAT WAS IN
 EFFECT AT THAT TIME HAS A 1 FOOT FREEBOARD THAT
 REQUIRES THE FINISH FLOOR AND EQUIPMENT TO BE A MINIMUM
 OF ONE FOOT (1') ABOVE THE BFE. THE PLANS SPECIFY A
 FINISH FLOOR ELEVATION OF 8' NGVD WHICH COMPLIES WITH
 THE FLOOD ORDINANCE IN EFFECT AT THE TIME OF
 APPLICATION. NOTE: ELEVATION CERTIFICATES WILL BE
 REQUIRED TO BE SUBMITTED DURING AND AFTER CONSTRUCTION.
  