Plan Review Notes
Plan Review Notes For Permit 17080635
Permit Number 17080635
Review Stop B
Sequence Number 1
Notes
Date Text
2017-08-25 15:42:04BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PLEASE SEE TRINITY EVALUATION REPORT FOR THE
 FOLLOWING COMMENTS:
 2. TWO DIFFERENT ROOF CLADDING DESIGN PRESSURES HAVE
 BEEN SELECTED, SEE PG. 2 OF 14 AND 3 OF 14. SELECT ONE.
 3. IDENTIFY IF STRUCTURE IS OPEN OR CLOSED.
 4. VULT SHALL BE 170 MPH. EXPOSURE IS C.
 5. SELECT PERIMETER & CORNER AREA ANCHOR SHEET
 ATTACHMENT.
 6. IDENTIFY WHICH SYSTEM WILL BE INSTALLED, SEE PAGES 3
 OF 14 THRU 13 OF 14.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
  
  
  
  
  