2017-10-04 17:21:55W. P. B. REVISION: 17080125 CORRECTED NOTES!
 W. P. B. PERMIT: 15111020 NOT: 15050292/ FOUNDATION
 PERMIT
 ADD: 1100 S. FLAGLER DR. SUITE: UNIT 9B
 CONT: SUFFOLK
 TEL: 561-407-496-3168 ED HANRATTY
 E-MAIL: NO E-MAIL ADDRESS/ USING OLD FORM, NEW FORM HAS
 E-MAIL ADDRESS REQUIREMENTS,
 WE PREFER TO COMMUNICATE BY E-MAIL TO HAVE A WRITTEN
 RECORD.
  
 2010 FLORIDA BUILDING CODE W 2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 SUBJECT TO FAIR HOUSING!
  
 1ST REVIEW
 DATE: MON. OCT. 02/2017
 ACTION: DENIED
  
 1) SHEET 126-18-A2-90-9B SHOWS (2 POCKET DOORS U04B &
 U05B) LEADING INTO THE MASTER BATH HIS & HERS. THE
 DOORS AS SHOWN IN THE OPEN POSITION MEASURE 2.50 FT.
 FAIR HOUSING REQUIRES A CLEAR WIDTH OF 32 INCHES. 2014
 FBC- ACCESSIBILITY/ FAIR HOUSING SECTION
 100.205.(C)(2)(2).
  
 1B) SHEET 126-18-A2-90-9B SHOWS (2 POCKET DOORS U04B &
 U05B) LEADING INTO THE MASTER BATHROOMS HIS & HER
 BATHROOMS. PLEASE PROVIDE WHAT TYPE OF HANDLES WILL BE
 INSTALLED ON THE POCKET DOORS CANNOT BE FULLY RECESSED
 HARDWARE HAS TO BE ACCESSIBLE FOR PEOPLE THAT HAVE
 LIMITED HAND MOBILITY.
 2014 FBC- ACCESSIBILITY/ FAIR HOUSING SECTION
 100.205(C)(2)(2).FIGURE 1( C ).
  
 1C) SHEET 126-18-A2-90-9B SHOWS (2 POCKET DOORS U05W &
 U05V) LEADING INTO BOTH HIS AND HER MASTER CLOSETS. THE
 DOORS AS SHOWN IN THE OPEN POSITION MEASURE 2.50 FT.
 FAIR HOUSING REQUIRES A CLEAR WIDTH OF 32 INCHES. 2014
 FBC- ACCESSIBILITY/ FAIR HOUSING SECTION
 100.205.(C)(2)(2).
  
 1D) SHEET 126-18-A2-90-9B SHOWS (2 POCKET DOORS U05W &
 U05V) LEADING INTO BOTH HIS AND HER MASTER CLOSETS. .
 PLEASE PROVIDE WHAT TYPE OF HANDLES WILL BE INSTALLED
 ON THE POCKET DOORS CANNOT BE FULLY RECESSED HARDWARE
 HAS TO BE ACCESSIBLE FOR PEOPLE THAT HAVE LIMITED HAND
 MOBILITY. 2014 FBC- ACCESSIBILITY/ FAIR HOUSING SECTION
 100.205(C)(2)(2).FIGURE 1( C ).
  
 1E) SHEET 126-18-A2-90-9B PLEASE BE AWARE ALL OF THE
 EXTERIOR SLIDING GLASS DOORS WILL NEED TO MEET THE 32
 INCHES CLEAR AND THE HARDWARE HAS TO BE ACCESSIBLE FOR
 PEOPLE THAT HAVE LIMITED HAND MOBILITY.
 2014 FBC- ACCESSIBILITY/ FAIR HOUSING SECTION
 100.205.(C)(2)(2).FIGURE 1( C ).
  
 2) SHEET 208-18-A6-25-9B FLOOR FINISHES WOOD FLOORS AND
 TILE FLOORS. BLDG TYPE: TYPE I/ TYPE II FLOOR
 INSULATION (FBC-B 2014)
 FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL
 NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR
 ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE
 QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A
 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
 2A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 2B) FBC-B 2014 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 2C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 2D) THE PLAN DOES NOT SAY IF THE WOOD FLOORS ARE GOING
 TO HAVE AN UNDERLAYMENT ONLY. IF THE FLOORS ARE GOING
 TO USE WOOD SLEEPERS AND THEN COMPLIANCE WILL BE
 REQUIRED UNDER 2010 FBC-B:
 805.1.1 SUBFLOOR CONSTRUCTION.
 FLOOR SLEEPERS, BUCKS AND NAILING BLOCKS SHALL NOT BE
 CONSTRUCTED OF COMBUSTIBLE MATERIALS, UNLESS THE SPACE
 BETWEEN THE FIRE-RESISTANCE-RATED FLOOR ASSEMBLY AND
 THE FLOORING IS EITHER SOLIDLY FILLED WITH
 NONCOMBUSTIBLE MATERIALS OR FIREBLOCKED IN ACCORDANCE
 WITH SECTION 718, AND PROVIDED THAT SUCH OPEN SPACES
 SHALL NOT EXTEND UNDER OR THROUGH PERMANENT PARTITIONS
 OR WALLS.
  
 805.1.2 WOOD FINISH FLOORING.
 WOOD FINISH FLOORING IS PERMITTED TO BE ATTACHED
 DIRECTLY TO THE EMBEDDED OR FIREBLOCKED WOOD SLEEPERS
 AND SHALL BE PERMITTED WHERE CEMENTED DIRECTLY TO THE
 TOP SURFACE OF FIRE-RESISTANCE-RATED FLOOR ASSEMBLIES
 OR DIRECTLY TO A WOOD SUBFLOOR ATTACHED TO SLEEPERS AS
 PROVIDED FOR IN SECTION 805.1.1.
  
 3) THE NARRATIVE LIST SHEETS A0.01C, A2.56A, A6.13A &
 A7.55A WITH ADDED REFERENCED NOTES BUT THESE SHEETS ARE
 NOT IN THE PERMIT PACKAGE. 107.2.1.3 ADDITIONAL
 INFORMATION REQUIRED. SUBMIT IF THEY ARE PART OF THIS
 REVISION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
2017-08-29 14:31:49W. P. B. REVISION: 17080125
 W. P. B. PERMIT: 15111020 NOT: 15050292/ FOUNDATION
 PERMIT
 ADD: 1100 S. FLAGLER DR. SUITE: UNIT 9B
 CONT: SUFFOLK
 TEL: 561-407-496-3168 ED HANRATTY
 E-MAIL: NO E-MAIL ADDRESS/ USING OLD FORM, NEW FORM HAS
 E-MAIL ADDRESS REQUIREMENTS,
 WE PREFER TO COMMUNICATE BY E-MAIL TO HAVE A WRITTEN
 RECORD.
  
 2010 FLORIDA BUILDING CODE W 2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 SUBJECT TO FAIR HOUSING!
  
 1ST REVIEW
 DATE: TUESDAY AUGUST 29/2017
 ACTION: DENIED
  
  
 1) SHEET 242.17B-A6-68-9A ENLARGED PLAN- DETAIL 1 /
 BATHROOM # 2 (SPEC. B) INDICATES REINFORCEMENT FOR
 OPTIONAL WALL MOUNTED SEAT AT 24 INCHES A.F.F. PLEASE
 PROVIDE IS THE 24 INCHES THE TOP OF BACKING, CENTER
 LINE OF BACKING AND WHAT IS THE HEIGHT OF THE BACKING.
 THE FAIR HOUSING CODE REQUIRES BACKING FOR TUBS AND
 SHOWERS, AND FOR 36 X 36 INCH SHOWERS THE SHOWER STALL
 SEAT MUST HAVE REINFORCING TO ALLOW FOR THE
 INSTALLATION OF AN OPTIONAL WALL HUNG SEAT. FAIR
 HOUSING ALSO USES THE ANSI A117.1 AND FOR SEATS IN
 SHOWERS SHALL BE 17 INCHES MINIMUM TO 19 INCHES MAXIMUM
 ABOVE THE BATHROOM. THE BACKING HAS TO BE IN HEIGHT
 PLACED TO MEET THE HEIGHT REQUIREMENTS FOUND UNDER FAIR
 HOUSING AND ANSI A117.1. IF THE DESIGNER WISHES TO HAVE
 BACKING AT A HIGHER HEIGHT FOR A FUTURE SEAT THEY WILL
 ALSO NEED TO MEET THE REQUIRED BACKING RANGE BY THE
 CODE. PLEASE ADD THE ADDITIONAL BACKING REQUIRED AND
 CLARIFY WHAT THE 24 INCHES ABOVE FINISH FLOOR IS
 RELATIVE TOO.
  
 2) THE NARRATIVE FOR THE ARCHITECTURAL PLANS AGAIN
 REFERENCES 4 SHEETS NOT FOUND IN THE REVISION SET OF
 PLANS, A).01C, A2.56A, A6.13A & A7.55A. W. P. B.
 ADMINISTRATIVE CODE 107.2.1.3 ADDITIONAL INFORMATION IS
 REQUIRED.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  