2017-08-03 15:53:34 | BUILDING PLAN REVIEW |
| 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER, PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| |
| 1ST REVIEW |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. PROVIDE LEGIBLE PLAN. |
| FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS |
| SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON |
| SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. |
| THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, |
| SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO |
| RECORDS MANAGEMENT. |
| |
| 2. PROVIDE DETAIL OF POOL BARRIER GATE. |
| R4501.17.1.8 |
| ACCESS GATES, WHEN PROVIDED, SHALL BE SELF-CLOSING AND |
| SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS |
| R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE EQUIPPED |
| WITH A SELF-LATCHING LOCKING DEVICE LOCATED ON THE POOL |
| SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS LOCATED |
| NO LESS THAN 54 INCHES (1372 MM) FROM THE BOTTOM OF THE |
| GATE, THE DEVICE RELEASE MECHANISM MAY BE LOCATED ON |
| EITHER SIDE OF THE GATE AND SO PLACED THAT IT CANNOT BE |
| REACHED BY A YOUNG CHILD OVER THE TOP OR THROUGH ANY |
| OPENING OR GAP FROM THE OUTSIDE. GATES THAT PROVIDE |
| ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM |
| THE POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING |
| GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457 |
| MM) OF THE RELEASE MECHANISM. |
| |
| 3. DESIGNER TO PRINT NAME AND SIGN PLAN. |
| THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE |
| THEIR PRINTED NAME AND SIGNATURE ON THE SUBMITTED PLANS |
| AND SUPPORTING DOCUMENTS PER FBC 107. |