Plan Review Notes For Permit 17070856 |
Permit Number |
17070856 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2017-07-31 15:16:59 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- FLAT ROOF NOA 14-0529.02 SUBMITTED: PROVIDE SIGNED | | AND SEALED RAS 117 CALCULATIONS AS REQ'D GENERAL | | LIMITATION #7. | | | | 2- ARCHITECT TO REVISE THE DESIGN PRESSURES FOR THE | | OVERHEAD GARAGE DOOR TO CORRESPOND TO EXPOSURE "D". SEE | | SHEET A3.1 | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: | | A) BALCONY DECK UNDERLAYMENT. NOTE: NEED PRODUCT | | APPROVAL THAT IS DESIGNED TO BE USED WITH THE SPECIFIC | | DECK FINISH MATERIAL TO BE INSTALLED IN THIS HOUSE. IN | | ADDITION CLEARLY IDENTIFY SPECIFIC ASSEMBLY TO BE | | INSTALLED AND PROVIDE SIGNED AND SEALED RAS 117 | | CALCULATIONS IF REQUIRED. | | | | B) ROOF CLAY TILE. NOA 12-0210.01 SUBMITTED EXPIRED ON | | 02/01/16. | | | | C) ROOF TILE ADHESIVE. SEE ROOF TILE PRODUCT APPROVAL | | FOR LISTED ADHESIVES. | | | | D) OVERHEAD GARAGE DOOR THAT MEETS THE DESIGN PRESSURES | | CALCULATED BY THE ARCHITECT OF RECORD. COORDINATE WITH | | ITEM #2 ABOVE. | | | | E) SINGLE HUNG WINDOWS. NEED LARGE MISSILE IMPACT | | RESISTANT PRODUCT APPROVAL. NOA 15-0512.08 SUBMITTED IS | | FOR SMALL MISSILE IMPACT RESISTANT. | | | | F) WINDOW MULLIONS AS SHOWN ON PLANS. AND, SPECIFY | | MULLION SIZE. | | | | G) FIXED WINDOWS AS SPECIFIED ON PLANS. | | | | H) GUEST HOUSE EXTERIOR SWING DOOR AS SHOWN ON PLANS. | | | | 4- ARCHITECT OF RECORD TO REVIEW AND APPROVE ABOVE | | PRODUCT APPROVALS. |
|