2017-08-22 08:40:22 | 1ST REVIEW: FBC 2014 5TH EDITION |
| |
| PLUMBING COMMENTS: |
| |
| 1. THE WALLS AROUND THE MOP SINK SHALL COMPLY WITH FBC |
| B 1210.2.2 |
| |
| 2. PLEASE SHOW COMPLIANCE WITH FBC ACC 604.7 |
| DISPENSERS. |
| TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| THE CENTERLINE OF THE DISPENSER. |
| |
| 3. THE SIDE GRAB BAR FOR THE TOILET SHALL COMPLY WITH |
| FBC ACC 604.5.1 SIDE WALL. |
| THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 MM) |
| LONG MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM |
| THE REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM |
| FROM THE REAR WALL. |
| |
| 4. PLEASE SHOW DIMENSIONS FOR SHOWER SEAT PER FBC ACC |
| 610.3 SHOWER COMPARTMENT SEATS.IN TRANSFER-TYPE |
| SHOWERS, THE SEAT SHALL EXTEND FROM THE BACK WALL TO A |
| POINT WITHIN 3 INCHES (75 MM) OF THE COMPARTMENT ENTRY. |
| THE TOP OF THE SEAT SHALL BE 17 INCHES (430 MM) MINIMUM |
| AND 19 INCHES (485 MM) MAXIMUM ABOVE THE BATHROOM |
| FINISH FLOOR. SEATS SHALL COMPLY WITH 610.3.1 OR |
| 610.3.2. |
| 610.3.2 L-SHAPED SEATS. |
| THE REAR EDGE OF AN L-SHAPED SEAT SHALL BE 21/2 INCHES |
| (64 MM) MAXIMUM AND THE FRONT EDGE 15 INCHES (380 MM) |
| MINIMUM AND 16 INCHES (405 MM) MAXIMUM FROM THE SEAT |
| WALL. THE REAR EDGE OF THE L PORTION OF THE SEAT SHALL |
| BE 11/2 INCHES (38 MM) MAXIMUM FROM THE WALL AND THE |
| FRONT EDGE SHALL BE 14 INCHES (355 MM) MINIMUM AND 15 |
| INCHES (380 MM) MAXIMUM FROM THE WALL. THE END OF THE L |
| SHALL BE 22 INCHES (560 MM) MINIMUM AND 23 INCHES |
| MAXIMUM (585 MM) FROM THE MAIN SEAT WALL. |
| |
| 5. PLEASE SHOW COMPLIANCE WITH FBC ACC 608.5.1 TRANSFER |
| TYPE SHOWER COMPARTMENTS. |
| IN TRANSFER TYPE SHOWER COMPARTMENTS, THE CONTROLS, |
| FAUCETS, AND SHOWER SPRAY UNIT SHALL BE INSTALLED ON |
| THE SIDE WALL OPPOSITE THE SEAT 38 INCHES (965 MM) |
| MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE |
| SHOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL WALL |
| 15 INCHES (380 MM) MAXIMUM FROM THE CENTERLINE OF THE |
| SEAT TOWARD THE SHOWER OPENING. |
| |
| 6. IN THE SHOWER ONLY ONE GRAB BAR IS SHOWN ON BACK |
| WALL PLEASE SHOW COMPLIANCE WITH FBC ACC 608.3.1 |
| TRANSFER TYPE SHOWER COMPARTMENTS. |
| IN TRANSFER TYPE COMPARTMENTS, GRAB BARS SHALL BE |
| PROVIDED ACROSS THE CONTROL WALL AND BACK WALL TO A |
| POINT 18 INCHES (455 MM) FROM THE CONTROL WALL. |
| |
| 7. A BACKFLOW IS REQUIRED ON THE ICE MACHINE AND THE |
| COFFEE MACHINE. PER FBC PL 608.3, 608.16.10 |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| THE PREVIOUSLY REVIEWED SHEETS. |
| |
| GEORGE JOHNSON |
| PLUMBING PLANS EXAMINER |
| CITY OF WEST PALM BEACH |
| 561-805-6711 |
| [email protected] |
| |