2017-07-28 12:34:08 | 2014 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 17070728 |
| ADD: 1701 S. FLAGLER DR. SUITE: 204 |
| CONT: MARYJULI CONSTRUCTION |
| TEL: 561-386-6032 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: FRI. JULY 28/ 2017 |
| ACTION: DENIED |
| |
| 1) SHEET 1 DOES INDICATE A CEILING PLAN WHERE THE DROP |
| CEILING (SOFFIT) IS BEING REMOVED. THERE IS A NOTE TO |
| REFINISH THE CEILING WITH ? INCH METAL FURRING AND ? |
| INCH GYPSUM BOARD. THE PLANS DO NOT PROVIDE A CODE |
| COMPLIANT CEILING OVER THE NEW SHOWER AREA AND |
| ENCLOSURE. PLEASE SHOW HOW COMPLIANCE WILL BE MET; |
| 2509.3 LIMITATIONS. |
| WATER-RESISTANT GYPSUM BACKING BOARD SHALL NOT BE USED |
| IN THE FOLLOWING LOCATIONS: |
| (3). ON CEILINGS WHERE FRAME SPACING EXCEEDS 12 INCHES |
| (305 MM) O.C. FOR 1/2-INCH THICK WATER-RESISTANT GYPSUM |
| BACKING BOARD AND MORE THAN 16 INCHES O.C. FOR 5/8-INCH |
| THICK WATER-RESISTANT GYPSUM BACKING BOARD. |
| 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |