Date |
Text |
2017-08-18 12:21:01 | 2014 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 17070265 |
| ADD: 501 S. FLAGLER DR. SUITE : 302 |
| CONT: ANDERSON MOORE CONSTRUCTION |
| TEL: 561-308-1590 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 3RD REVIEW |
| DATE: FRI. AUG. 18/ 2017 |
| ACTION: BUILDING PROVISO |
| |
| 1) PROVISO: 2014 ACCESSIBILITY CODE SECTION 404.2.4 |
| MANEUVERING CLEARANCES, MINIMUM 18 INCHES |
| LATCH SIDE OF DOOR. TABLE 404.2.4.1 AND FIGURE |
| 404.2.4.1(A). |
| |
| 2) PROVISO: POCKET DOORS, DOORS ARE IDENTIFIED AS 313B |
| & 314B. |
| 2014 ACCESSIBILITY CODE 404.2.7 DOOR HARDWARE. WHERE |
| SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING |
| HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. |
| HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE |
| PARTS ON DOORS AND GATES SHALL COMPLY WITH 309.4. |
| OPERABLE PARTS. |
| 2014 ACCESSIBILITY CODE 309.4 OPERATION. OPERABLE PARTS |
| SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE |
| TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE |
| FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 |
| POUNDS MAXIMUM. |
| |
| JAMES A. WITMER BN, PX, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| DEVELOPMENT SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| |
| |